Search results

  1. P

    Hot radiator

    After trading blows :) I had a plumber come around. The diagnosis he made is that the previous plumber has most likely teed off the return flow for hot water. He said the bypass had no flow in it. Apart from ripping up floors etc he suggested thermostatic valve as a cheaper/easier fix.
  2. P

    Resilliance bars or x2 soundblock

    For the wall I thought the air gap was the bit that you needed? ie don't pack it out with rockwall. I will be putting that in the floor
  3. P

    Flooring

    is that Buy? Cheers :)
  4. P

    Flooring

    I'm redecorating a bedroom and i can hear everything from the front room. I'm going to install acoustic rockwall in the cavity as there is nothing in there. However the flooring is old interlocking t&g. There are lots of gaps from various plumbing over the years. It was suggested i rip it up...
  5. P

    Resilliance bars or x2 soundblock

    Hi I've got a partywall which isnt too bad for sound. As im decorating and installing a new ceiling i wondered what would be more effective. Resilliance bars and 1x soundblock or 2x soundblock I don't want more than 1 with resilliance bars as i think i could lose too much. Any views please?
  6. P

    Hot radiator

    I've added a couple more photos. What is that black thing called? He said something about it be a safety bypass. It looks like it can be turned to adjust things. Would adjusting this make any difference? I can drain it down and fit a thermostatic valve. I am just not sure what this bit...
  7. P

    Hot radiator

    Hi, I've attached a photo. A plumber came around before Christmas and fitted what he called a safety bypass valve. I think he said it was to stop trapped hot water. I've just run the bath for 5 mins then stopped. When the HW came on it came up to the bottom of the 3 way value. It then went...
  8. P

    Hot radiator

    I will have a look at that. So can i turn off heating with just hot water on. Use some water and see what it does.
  9. P

    Hot radiator

    Ok cheers its odd that we have only just noticed it. Prev it went on with heating. The 3 way port is in our airing cupboard and the radiator which gets hot is in the loft. That radiator is higher than the valve.
  10. P

    Hot radiator

    Hi, I have a problem and I'm looking to diagnosis it. The heating has been off due the funny thing in the sky. When i have a shower the radiator (closet to tank and no thermostat fitted) in the bathroom becomes hot like the heating is on. Ive also had to top up the ch system which has gone to...
  11. P

    Faulty pressure washer

    At 200 red and black to motor measures 1.3 Red and blue 4.4 Red and white 0.3 Black blue 3.2 Black and white 1.5 Black and red 1.5 Blue white 4.8
  12. P

    Faulty pressure washer

    I will give this a go. I've got a dmm. I'm not a pro at using it i will let you know. Thanks for the help its appreciated
  13. P

    Faulty pressure washer

    I bypassed the switch and there was sadly no change. Maybe the motor is kaput
  14. P

    Faulty pressure washer

    Hi, i had a go at measuring voltage and resistance but didn't really have a clue. From the switch it was reading 120 to 140. I could probably do with a bit of a step by step to do it please? I turned the motor and some water came out. Still no joy on starting. After it wouldn't start last...
  15. P

    Faulty pressure washer

    I'm home on thursday to take a photo. I will try that process in pg10 of the user manual.. thanks for the help i really hope i get this going
  16. P

    Faulty pressure washer

    I've fitted the new Cap and absolutely nothing changed :( Now I am not sure what to do. After the cap it leads to a little black plastic box at the bottom. There is power to this but I don't know what it is. Back to the drawing board
  17. P

    Faulty pressure washer

    Hi thanks for the replies. I think the first safe and easy test is to replace the cap. I've ordered a new one. If that fails then onto the multimeter to try the other route. I will let know
  18. P

    Faulty pressure washer

    Hi, my dad gave me a clarke pressure washer 140. I used it yesterday to blast the patio and it worked like a dream. Today i went to use it and nothing happened. No fuse blown no noise just silence. It was suggested that the capacitor could be faulty. Sadly my dad passed away recently so i...
  19. Washer

    Washer

  20. P

    Gap under window

    Its a first floor window next to a pitched roof. It was only in the recent cold i noticed how chilly it was. When i stuck my head out i spotted the gap. Its not really visible from the ground. Thanks for the advice I've just given my foam gun a good clean up
Back
Top