  1. J

    black smoke boiler problem

    O/P: Is your vent at low level connected to the boiler burner by a flexible tube ?.
  2. J

    Grant Combi 90 losing pressure

    Sounds as if your problem is the vessel, if there is crud and wet round the top of the auto a/v then it is knackered, the p-r-v will most probably be fine.
  3. J

    Grant Combi 90 losing pressure

    As oilman has allready said useing the p-r-v to drop the pressure is a good idea, as this checks to make sure it will open, this is the method I use at a service. Aim for 0.8 to 1.0 air pressure at 0.0 system presure, the other weak point on the grant is the cheapo auto air vent, it is worth...
  4. J

    Good hole saw for 4" cast?

    oilman:What do you use covers after cutting ?. I usually end up robbing chrome covers off of bends !.
  5. J

    Grant Combi 90B3 HELP

    This is a G5B burner , most odd a 90 v3 should have a RDB, to get at the oil pump undo the 4 screws in the corners of the metal burner cover, the bleed port is on the front of the oil pump and needs a 15mm socket to loosen it.
  6. J

    riello burner motor buzzing and then lock out

    Are you sure the new pump is not duff ? , riello have big problems with pumps at the moment.
  7. J

    PERRYMATIC WF80

    Stupid question perhaps but have you reset the trip on the front of the OCV, Is the secondry float chamber full stopping the OCV refilling.
  8. J

    Bentone B9A burner/Worcester danesmoor 12/14

    O/P: You have probably wrecked your AS47C pump and the drive coupler, the correct pump is a BFP41L3 !!. AGILE: How sad are you looking up O/P'S planning OILMAN:mainly mixed farming in that area, but take your wellies anyway :lol: TERRYWOOKFIT: spot on
  9. J

    Bentone B9A burner/Worcester danesmoor 12/14

    with a B9 it would be norm to see a danfoss bfp pump, do you have a good fuel flow?, do you have a 1 or 2 pipe supply?, what is the new pump set-up for 1or 2 pipe?,is the new pump the correct rotation?. Just a few thoughts, still with grain at £175 a ton you could get someone who knows what...
  10. J

    Oil fired central heating - oil consumption

    Employ a good heating engineer, get him to heatloss rooms and check rad sizes are correct, then total them up plus dhw to find boiler output, check burner is set to correct output for system. Your frost stat needs to be wired with a pipe stat to stop boiler running for longer than needed, ask...
  11. J

    Riello oil burner advice please

    The stem on a riello fuel pump closes when energized !.
  12. J

    Lock out Firebird Super 50/82

    1. open the front of the boiler 2. if there is a large metal box at the bottom , release the clip and remove the box. 3. you should now be able to see the glowing button, as said already only re set it twice , if it fails to stay on you will need a engineer. GOOD LUCK
  13. J

    Firebird Super Q Boiler 50/82

    If its the combi it has a relay under the top of the front facia, this has a permanent live so if it sticks could keep the boiler running.
  14. J

    Getting rid of oil central heating - domestic hot water

    Your boiler will be fine for underfloor, I fitted one 18 months ago useing a thermal store to stop short cycling, the underfloor has a mixing valve to blend down to about half the boiler flow temperature. INMO anyone fitting electric underfloor out of choice is ill informed and will live to...
  15. J

    Floor standing boiler for a gravity central heating system??

    All the mexico he units I have seen have 3 tappings off the bottom, a gas inlet, and a pair of c/h (flow and return)
  16. J

    water heater....diesel or gas....any ideas for me?

    Vailant used to make a small multipoint water heater that could be used on lpg , can't remember the model or output but they were fitted to lots of static caravans, palamo also made one that had a low pressure option(12 volt pump) both are conventional flue and heat water on demand.
  17. J

    Rayburning question!

    Flue lining is a important factor in any conversion, and since scaffolding is now required for most jobs even more important to cost . Even a guestimate needs to factor this cost in to have any chance of being of any worth.
  18. J

    Rayburning question!

    OILMAN, What about flue lining cost and scaffolding an extra £750 at least, also big difference in cost depending on which conversion kit is used type of cooker etc (regent or suppreme). You need more info before you can start to" guestimate" such a job.
  19. J

    Magnaclean versus Spirovent

    make sure the system is flushed well and go for the magnaclean £85 seems very reasonable.
  20. J

    SERVOWARM Manual Diverter Valve (Jammed solid)

    the most cost effective option all round would be to change to a Y-plan