Search results

  1. S

    Vokera Linea 24 showing 04 error code

    Right That sounds easy enough .... Thanks alot mate i will give that a go when i get home from work and post the results to help others out )) Cheers Nickso your the Man :D
  2. S

    Vokera Linea 24 showing 04 error code

    i flushed the rad system with some fernox cleaner .. in a mastic tube cannot remember the full name .... thats why i took the plate off cause i read that the crap floating around in the rad system can block it up. basically just tapped and flushed with water over and over till ran clear
  3. S

    Vokera Linea 24 showing 04 error code

    do you both argue all the time lol .. i have seen it on other forum.. i will have to look for the non return valve i am unsure where that is .... i have had the plate heat exchanger out so thats not a problem.. thanks again guys i will give it a try... p.s can the plate heat exchanger be...
  4. S

    Vokera Linea 24 showing 04 error code

    i have had the heat exchanger out before to clean out as read in a forum before or does this not work?
  5. S

    Vokera Linea 24 showing 04 error code

    no it just seems to go out not modulate. also just to add to this .. i have just turned the hot tap on in the kitchen full and the temp goes no higher than 30c and when i turn a cold tap on a bit to slow the flow in the boiler the water warms to 41c then flames out then re-ignites ...
  6. S

    Vokera Linea 24 showing 04 error code

    Hi again . it says in the manual that its a pressure switch , like a plunger that comes out and makes contact with the micro switch i understood that was what you was talking about when you said to short the wires out. which i did and the fault went ... But my DHW still goes hot and cold i...
  7. S

    Vokera Linea 24 showing 04 error code

    Hi Again, Tried what you recommened by shorting the micro switch wires on the pressure switch and this worked a treat. bought a new micro switch for £15 all seems fine...... ( turned out to be a faulty micro switch).... thanks for the info :D
  8. S

    Vokera Linea 24 showing 04 error code

    Thanks Nickso i will give that a try and post my findings :)
  9. S

    Vokera Linea 24 showing 04 error code

    Hi Nickso, Yes there is a pressure switch next to the pump also it has a Domestic Hot Water Flow Switch on the cold water inlet. i have changed the flow switch before approx 2 years ago. i have also fitted pressure vessel and MCB also 2 or 3 motorised valves main heat exchanger and cleaned...
  10. S

    Vokera Linea 24 showing 04 error code

    Hi Guys, i won't sound like i know whats happening but heres what i know. My boiler central heating is working fine or seems to be. My domestic hot water goes hot and cold and today it has started to flash up the error code 04. which i know is low pressure of poor flow in system. my...
Back