Search results

  1. J

    radiators

    i have a pin prick hole in my rad. its quite big rad 1600x600, is there any chance i can repair it without changing it.
  2. J

    room stat

    have a problem with my room stat. boiler does not turn off when temp. is reached and even the timer will not turn it off when it reaches time,can only turn off manually
  3. J

    central heating

    have a problem with heating. rads are sometimes luke warm and sometimes hot. boiler does not turn off when it reaches stat temp. and boiler makes a bit of a glugging noise sometimes. i recently had a new pump put on after it burnt out just after a couple of new rads were put on.
  4. J

    cold feed to toilet

    so are you saying that i should have drained it before cutting it.
  5. J

    cold feed to toilet

    Why is it when i cut the cold pipe to fit to new toilet, it continually bubbled over even though the stop valve was turned off and the cold distribution from the cistern was off and also i drained from the drain off by the stop valve.
  6. J

    Capping rad pipes

    i would do it inside but the guy said he cannot be bothered to drain the system and wants to just cut it and cap it
  7. J

    Capping rad pipes

    Iwant to cap a flow and return rad pipes for a couple of months, is it ok to use push fit cap ends. Also these 2 pipes are outside as they were originally in a consevatory that has now been taken away. Thanks
  8. J

    pressure testers

    Anybody know the best place to go for a pipe hydraulic pressure tester
  9. J

    soldering

    i drained it down but naybe there is still some in there how do i get rid of it
  10. J

    soldering

    Can anyone tell me why after i soldered some pipe yesterday it leaked so i have come back today to do it but the solder will not stick, any solutions would be grateful
  11. J

    i need help

    Thanks for the advice. I'll give it a try.
  12. J

    i need help

    How can I tell if the pump is working? wouldn't hot water rise so far anyway, without the use of a pump? Thanks.
  13. J

    i need help

    So if I turn all the upstairs radiators off, and the other downstairs ones, should that be enough to get some heat to the other two? As regards to the pump, how many speeds are there? Thanks.
  14. J

    i need help

    yes it is in the hot section of the pipe. How do I resolve this situation? There must be an easier way than putting bleed valves in. Thank you.
  15. J

    i need help

    but these were there originally and it worked then and there are 2 thumb bleed valves where the pipes enter the loft.At its highest point.
  16. J

    i need help

    I have just hung a new rad on the other side of the room to replace an old one. I connected the pipework to the rad that was on the other side of the wall and after testing for leaks filled the system and turned on the boiler.Now all the upstairs rads work and some of the downstairs, BUT the...
  17. J

    testing for leaks

    I have recently hung two rads and would like to check for leaks before i connect to other pipework, i dont have a pressure tester can anyone give me a simple solution.
  18. J

    draining rad system

    I will be draining all radiators down, do i turn off the supply at the feed and expansion cistern?
  19. J

    HOT RADIATORS

    thanks, will look into it
  20. J

    flushing radiators

    I am in the process of hanging some radiators, and connecting relative pipework , how do i go about flushing the system once i have finished.