Search results

  1. T

    Heat pump

    ASHP's cost more to run in the winter because of the lower air temp. At the time of year you need it it costs you a fortune to run. The colder the outside temperature and the warmer the temp you want from it the more expensive it becomes. Regards.
  2. T

    ideal isar 30he boiler - any good??

    LOL. Are you sure. If you give something a 5 year guarantee its because you are confident in the product and not because its going to break down!!!! :roll: :roll: Regards
  3. T

    PV cells?

    There is a scheme which is due to start with P.V. which could mean a very quick payback on the investment. Feed in tarriffs will pay the householder with P.V. installed, for all electricity that is not used that gets put back into the grid. This payment will be given back to the customer as a...
  4. T

    Ideal Logic

    even more so if BG didn't insist on fitting them. BG havent pushed Ideal for years. Thery have badged up Worcesters as you know as their main boiler for a few years now. Regards
  5. T

    Ideal boiler HE C22/24 problem

    A regular problem for any boiler fitted on a dirty system. Regards.
  6. T

    Ideal boiler HE C22/24 problem

    I have a question for you. Is the hot water performance good from all of your hot water taps? If the hot water supply from your taps is good, then the problem must lie with the mixer part of your shower. What type of shower do you have? If your hot water perfomance is poor...
  7. T

    Ideal Logic

    I have fitted a few of these and are my number one choice that i push to customers. Easy to fit etc, and i have had no problems at all. People will install what they are used to and a brand that they can trust and i think that is why there seems to be some reluctance from some to try the...
  8. T

    Ideal Logic Plus

    Fitted a few and have one in my own house. Was sceptical at first but gave them a go and so far i am very happy and so are my customers. Easy to fit and commision. 5 year warranty with the plus. Would recommend. Regards
  9. T

    2 system boilers

    Pipe the two boilers together on a reverse return arrangement. If they are not piped up in this way then one boiler will do all of the work and wear out quicker. Regards
  10. T

    Heat pump

    lol :lol: :lol:
  11. T

    Heat pump

    Ground source heat pump installations are very expensive and are around 400% efficient Air source heat pump installations are cheaper but the efficiency drops to around 300% but can drop even further dependant on what the outside temperature is and what temperature you are heating the water...
  12. T

    Central Heating LPG

    Use Propane. Butane is normally used for leisure appliances such as BBQ's and patio heaters etc. Regards.
  13. T

    Vaillant Turbomax Plus 824e - No CH or HW

    You still have a blockage somewhere in the boiler. The problem with all of that 'black rubbish' as you call it, can affect so many components in the boiler. Pump Main Heat Exchanger, Plate Heat exchanger, Diverter valve. Get your system and boiler completely cleaned and flushed...
  14. T

    WB 30CDI or IDEAL LOGIC + COMBI

    I have fitted Logics. No problems so far and my customers are very happy. Go for the Logic plus which has a 5 year guarantee. Boiler needs to be serviced every year and as long as it is, the boiler is covered parts and labour. Have put one in my own house as well as. Regards.
  15. T

    Ideal Isar HE35 - DHW ok, no CH

    Does the boiler always show 0 in the display, even when your external timers and room stat are on and calling for heat? If this is the case then you will have a problem with your external controls (faulty timer, room stat or wiring problem). Regards.
  16. T

    Ideal Icos HE18 boiler Code P information required

    P on an Icos display means frost protection. I would assume that the Icos has an orange cicuit board as 'P' doesnt appear on Icos boilers with older black pcb's. Regards.
  17. T

    Outdoor boiler

    Vokera do the balcony boiler which i believe is rainproof. Regards
  18. T

    Ideal logic

    If you look inside most boilers they all use similar parts and componenets. Not many manufacters actually make their own parts. If you look at broucheres in merchants they all use the same wireless controls and clocks etc. Most or a large number of diverter valves are Honeywell, Honeywell...
  19. T

    Vulcan Continental boiler

    This boiler will definately qualify for the new scrappage scheme. Take advantage of it and get it replaced. Regards.
  20. T

    vaillant turbo max vuw 242 E

    The diverter valves on these boilers were and still are a weak point. If used in a comercial premisis i imagine that the diaphram wears out very quickly. Regards
Back
Top