  1. B

    air in central heating

    Bobby,it seems like its losing water somewere if your venting the rads ,so unless youve a leak under the floor and its ok when the heats on and doesnt start until the system is stone cold and the tank cant reblenish it quick enough it must be a expansion proplem
  2. B

    Another Air in system problem

    is the tank full now and is it filling up when you vent the rads ,make sure the ballvalve is letting the water into the tank and no valves are off on the cold feed from the tank
  3. B

    Worcester 24i Ignition Problem

    is it trying to ignite can you see any sparking or a small flame in the boiler when trying c/.h
  4. B

    Worcester 24i Ignition Problem

    Firstly and no disrespect intended , have you checked the leads are all on 2 white leads and the harness can sometimes be a bit dodgy, if all ok then the new pcb might be bust,but check the leads ,is it sparking in the boiler or not,
  5. B

    Radiator valve

    it will have arrows pointing up and down v > like this if its just > and the other end is hot first then its wrong
  6. B

    air in central heating

    the header tank is at the min but the expansion is going into the cold feed so its low and with a powerful p[ump it will be pushing up is the water warm in the tank,why not think about making it a sealed system,with a expansion vessel ,will stop any of this trouble if ,pump lowered doesnt
  7. B

    air in central heating

    Turn pump down sounds like its pumping over,is your pump on 3,if so just turn down to 2
  8. B

    CENTRAL HEATING NOT WORKING

    turn the ones working off and then the ones not working turn off bar one if it heats up go to next rad that hasnt been ok and turn on and carry on like so,also the end with no trv ,lockshield valve when the rad is hot ,turn your non trv valve off and open it up just a bit about 2 -3 turns it...
  9. B

    Poterton Profile not firing up in the morning

    I had this proplem on a g/worm ultimate , not firing of a morning,but ok any other time of day and it had me baffled i went out there when it was meant to come on of a morning and it tried to ignite but wouldnt,anyway what it was,the gas valve was sticking overnight due to the cold wheather and...
  10. B

    radiator help:

    check at the back behind the rad at the top ,might be a myson rad which have vent at top right corner
  11. B

    Baxi boiler heating won't work

    If you have a mzv,use the manual lever when its on h/w and it will allow the c/h to heat up,if ok then leave the lever in the manaul position ,hooked in the slot and it should be a motor needed not a whole new valve
  12. B

    Condensing pipe run's?

    It is going into a drain which also has a 1 1/2 waste pipe from a flat going into it. Im sumising that if that's going into it, then i can?.Thanks
  13. B

    Urgent: Glow-worm Space-saver Mk 11

    1 is a heating flow 2 heating return 3 hot water circ flow 4 hot water circ return . top pipes are the flows .If you have a fully pumped system a pipe might be a cold feed from header tank to boiler .Have you got a mzv and pump or just a pump
  14. B

    Condensing pipe run's?

    Can i pick your brains please . I am a week into replacing 12 combi boilers and the new are condensing boilers .The only thing id like to ask is the condensing pipe can i just use overflow pipe and can i link them up as there flats and the top floor has 4 flats ,so can just run 1 pipe and tee in...
  15. B

    how do i know which is which?

    Your making it more difficult than it is.Get your rads and hang them up,get your valves on and run your pipework to the rads t off for your trv then for your l/shield carry on to rad 2 and connect into valves ,and trvs why make bi/directional if there not doing the job properley, cant be just to...
  16. B

    Airlock in cold water pipes?

    make sure you put it down the cold and not the hot .should have gate valves on turn one off until you know which is which.then carry on.
  17. B

    Airlock in cold water pipes?

    get a hose onto the cold tap in the bathroom and force it up so thewater goes back up into the tank and clears the airlock or in the loft get a bit of hose and feed it into the cold pipe so you will need a t shirt on so you dont get wet and just push it in the hole and put the hose on to were...
  18. B

    worcester boiler 240

    Apart from dont run out of gas. when you go to relight it turn the gas cookler on for 30 secs use 3 rings and turn them off,then go to your boiler and try it then,should be just air and need purging
  19. B

    Who has ignored someone?

    DID YOU HEAR SOMEONE THEN?
  20. B

    HHHHEEEELLLPPPP Low pressure from hot water & girgling.

    Have you a mixer tap, if so open hot tap fully and if you can open the cold and keep it from coming out the tap. It will travel up the hot tap and hopefully clear airlocks . It is better if you can just get a hose onto a hot tap from the mains and force it up and over the expansion .