  1. GodKnows

    Converting a balanced flue to a conventional flue

    Hi all, You must not like your life, or that of your family, or other people in your dwelling. What you are doing could be lethal :!: Unless you have had a brain transplant or care not a jot for life....... GET A GASSAFE ENGINEER ROUND TO LOOK AT IT YOU FRIGGIN IDIOT :roll: If...
  2. GodKnows

    Oh bother

    Hi all, You tight git, £40 over 27yrs :lol: Must only use one sheet of toilet roll per sitting :wink:
  3. GodKnows

    installing flow and return to central heating.

    Hi all, Normally best practise to fit flow on same side throughout, but, as long as you make sure you fit the TRV's on the flow pipe. Use bidirection TRV's and you won't have many problems...
  4. GodKnows

    Is the Quote very high : Moving Flue pipe 700+vat

    Hi all, Boxing in of flue pipe can only be done if access panels are fitted to inspect the FULL length of the flue. As of Jan 2013, your boiler will be classified as "At Risk" and any qualified GSR engineer will turn off your boiler :wink:
  5. GodKnows

    Banging noise in boiler + pressure loss in tap

    Why did you close your radiators off? In an O/V system you could be causing the boiler to overheat as the heat has nowhere too go! Surely, you just have to trun the heating off at the controls :roll: I suggest during the summer (If we get one) that once a month you turn your heating on to...
  6. GodKnows

    Plumber's Charges

    Hi all, Guess you must be a person who walks around waitrose and pick up your items without checking the price! Then, go to the till and complain about the total :roll: As with any trade, you are allowed to ask before they start work for a estimate or rough price :idea: Fool you for...
  7. GodKnows

    Ariston Microgenus 24 HE MFFI Help

    Hi Public, Some of these have a "comfort" button or "Eco.". This is on the left hand side of the panel. Either blue or green dial. Comfort setting keeps the DHW at a warm temperature in preparation for a draw off. Wasting some gas as well :? Turn it off, if you like...
  8. GodKnows

    Question about plastering...

    Hi all, The client is on holiday for two weeks and comes back on Monday coming. I'm completely tiling the bathroom in travertine, walls and floor. The problem I am concerned about is a couple of the walls were so badly out of plum I have replastered them out with bonding plaster up too two...
  9. GodKnows

    my myson apollo boiler

    Hi all, When the burner lights, does it sound like a kettle boiling with very little water in it? If so, the pump has probably failed :roll:
  10. GodKnows

    Strange water heating problem

    Hi all, Another case of contaminated water on the primary side of your boiler. Was the system flushed when it was fitted 4 years ago? Probably not, needs to be cleaned and inhibitor fitted! Bet no inhibitor in there either..... Quite a common problem when appliances aren't installed...
  11. GodKnows

    boiler not firing,return blocked???

    Hi all, OK, can you please check the last page on the installation booklet and see if he has commissioned your appliance? If he hasn't done that, or got someone else to do it, they haven't done the correct procedure maybe. If the boiler and system was checked properly on install, you...
  12. GodKnows

    Baxi platinum 33 combi boiler - your views please

    Hi all, Guess some people don't want to listen to professional advise :roll:
  13. GodKnows

    Baxi 105e No CH or HW Flame Failure and Fault on Flue or Fan

    Hi all, Get an experienced RGI out :roll: Second guessing and parts swopping isn't popular in our field. A waste of your money and our time :wink: A decent guy would take about 2 mins to suss out the problems with your boiler....
  14. GodKnows

    New bathroom questions

    Hi all, Please read carefully what TicklyT has posted :wink: You obviously don't understand schematics as you haven't grasped the principles between the difference of "Gravity" and "Sealed" systems.... The cold feed from the F & E tank is required with your system, and not "An...
  15. GodKnows

    Baxi platinum 33 combi boiler - your views please

    Hi all, OK, may I suggest you get a quote for a system boiler with an unvented cylinder of min 200 litres :wink: That would be suitable for a house of your size... Get a local RGI to quote for this and go from there.
  16. GodKnows

    Vokera Unica Syphon\trap question

    Same as your trap in a toilet, sink etc :wink:
  17. GodKnows

    Draining Central Heating

    Hi all, OK, you must turn off the boiler :shock: Without any water in the CH circuit it will over-heat and can crack the main HE. The boiler will be then dangerous and a costly replacement.... Check the fuse next to your HW tank for the immersion :wink:
  18. GodKnows

    baxi he 80 leaking water

    Hi all, Sounds like the DHW gland nut is passing water (common fault) unless the main part of the DV is weeping from a perished o ring. A picture is helpful, or an exact description of where the water is leaking out :wink: Get an RGI to have a look at it, simple fix....
  19. GodKnows

    Baxi 105e domestic hot water problem

    Hi all, OK, I hope that remark is directed as the clients plumber agile. I can suggest that probably the max + min burner settings need to be adjusted, and the DHW NTC would also need to be tested for correct operation. This should of been done at the service not long ago :roll...
  20. GodKnows

    Baxi 105e domestic hot water problem

    Ur primary side on the DHW plate HEX is clogged up with dirty water fella. Was system flushed and inhibitor put in on install? Inhibitor needs to be re-applied every five years ;)