  1. A

    Is this legal?!

    about the pump The pump is to boost water flow and works off a flow switch, so the pump will kick in every time a hw tap is activated.
  2. A

    motor overload

    The motor is driving a oil burner nu-way nol 25 The burner is from 1988 so motor has no data badge left on it. The overload was set at 1.5 amp and the other burner in the boiler house was set at 1.2 amp . So I think the last person just upped the amps on the overload. When reset the...
  3. A

    fan removal tool

    what is the tool called which holds the fan and had a screw which pushed the shaft from the motor from the fan ?
  4. A

    How many RGI's here Do their own electical Work.

    most people I would have thought, tho big companys still have sparks to fit the sparky bits for insurance reasons. With wireless controls getting more popular sparks wont be needed on most installs.
  5. A

    motor overload

    On a 3 phase motor which has a overload which had tripped could it have tripped due to the motor getting hot and drawing more current ? Went to job today where the overload had tripped and needed the button reset on the overload. Reset and the motor ran fine. This is the second time it has...
  6. A

    hole size ?

    whats next 40mm I think I will go with 20mm
  7. A

    hole size ?

    what size are the holes in a metal back box
  8. A

    heat loss from pipework

    what have you got 4 inch pipes in your house
  9. A

    heat loss from pipework

    how much heatloss as a percentage of your boiler will you get for insulated pipes uninsulated pipes
  10. A

    Wireless router question

    I think I need to type modem in as well
  11. A

    Wireless router question

    Hi I have a 2wire Homeportal 1800HG and wish to upgrade to a new wireless router. I was looking at them on amerzon and the pictures don't show where to plug my telephone line into the router. The router I have now is wireless but it drops signal 10 times a day and the range is not very good...
  12. A

    Ferroli Optimax He plus 35s

    Fault with this boiler can anyone help ? Got to boiler and controls calling for heat, on display boiler showing in CH mode. But pump runing and doing not else. Reset boiler and It fired then D2 came up on the display. Boiler got to about 30 and cut off pump still running. Reset...
  13. A

    help with boiler cutting out

    it is quite easy for a experienced boiler engineer to change the quickest way to solve this problem if the ev is failed is to put a expansion vessle on the return pipework to the boiler as you dont need to lift the boiler off the wall.
  14. A

    car tax and mot

    If a car were to be kept on a driveway does it have to be taxed and insured ?
  15. A

    London police station besieged by gang supporters

    The riots in london make me laght, the fact most of the rioters on the street could not even tell you the name of the man who got shot be the police. The rioters are just on the streets for a laught bacause there mates are out there throwing stones and bricks. And they can get away with it...
  16. A

    Proper term for filter cap on end of tap spout?

    could be water defuser. Thats what I would call it .
  17. A

    Manky Gunk in F/E Tank!

    Why dont you just seal the system and put a expanstion vessle and blow off valve on it. Check with manu if you can seal the boiler first.
  18. A

    Painting over fascia boards

    I am going to replace my gutters at the weekend as they are in a poor state so I am going to paint my fascia boards. Any tips on the correct way of painting them. They are brown with some bits of paint peeling but the wood is in good condition. Thanks ade
  19. A

    guttering

    can someone pease tell me the recommended spacing of gutter brackets
  20. A

    correct method of installing a strap on boss?

    Use a 54mm holesaw to cut hole Clean edges of hole with file Solvent weld strapon to stack Use rubber boss to conect 32 or 40mm pipe Simples :) Once you do it you will think that was easy :wink: