Search results

  1. E

    Shared Chimney Stack - Party Wall

    Hello Everyone If you are removing a shared chimney stack from a party wall, is there a minimum amount of chimney you need to leave before installing beams brackets etc? Just curious for the design of a room. Also is there any notice other than building regs required to be submitted, in...
  2. E

    Scratched MDPE

    Hello everyone If MDPE gets scratched, not deep but minor surface blemishes while being pulled through, will it effect joints? There not deep but you can feel them and see them just about. Also whats the best way to pull it through tight spaces? Should I wrap tape around the ends just...
  3. E

    32mm or 25MM MDPE

    Thanks for your reply As I was pulling the pipe through its gotten a little scratched, nothing too deep but minor surface blemishes that you can feel. Is this going to effect any joints I make? What woud you suggest I do about this if it is an issue, this is on the internal runs, it is...
  4. E

    32mm or 25MM MDPE

    Hello Everyone I currently have an incoming lead water main up to my internal stopcock, after the stop cock I have what appears to be 25mm mdpe running to my loft where it splits off into 22mm to feed my unvented cylinder. Is there any advantage in terms of flow rate for my cylinder...
  5. E

    15mm stop tap between 25mm mdpe and 22mm copper

    Full bore lever bought, push fit mdpe to 22mm reducer, thought I had 22mm pipe when I pulled it out was 28 arghh! Back to the merchants tmrw. Cheers
  6. E

    15mm stop tap between 25mm mdpe and 22mm copper

    Thanks for your reply Lever valves appear to be cheaper to. Many thanks
  7. E

    15mm stop tap between 25mm mdpe and 22mm copper

    Hello everyone Quick question In between 25mm mdpe and 22mm copper is a 15mm stop tap, 15mm copper has been fitted for about 10cm either side to create the connection. I have an unvented mains pressured system, do you guys think this 15mm bottle neck has any effect? Is it worthwhile...
  8. E

    Underfloor heating insulation cracking

    Original flooring is timber floorboards, spacing between joists is 300mm. Then 12mm ply screwed on top. XPS insulation boards. 3mm notched trowel Mapei Pro flexible. The floor is solid, no flexing nothing. The problem is when I laid the insulation I guess it didnt compress...
  9. E

    Underfloor heating insulation cracking

    Hello everyone I am tilling my floor with 12mm travertine and underfloor heating cable. I installed ply ontop of my floorboards and then used a flexible floor adhesive and fitted 6mm insulation ontop of the adhesive with a notched trowel. The only problem is now when I walk overe the...
  10. E

    New radiator on one pipe system, is this ok?

    The dot on the end of the feed pipe is the cap, that pipe was originally feeding the return but is not blocked. cheers
  11. Untitled

    Untitled

  12. E

    New radiator on one pipe system, is this ok?

    Yep it's just like the image, except that the left feed has an extra bit of copper with an end cap now.
  13. E

    New radiator on one pipe system, is this ok?

    Well the other end goes to the original tee but as its disconnected its been capped. The other end of the new connection is more than a meter away from the tee out of the ring.
  14. E

    New radiator on one pipe system, is this ok?

    Ok so the new piping has been done, the pipe run from the main circuit is about 1.5 meters! So I think plenty of space. The pipe with the end cap was the original connection but has now been capped, the distance from the feed was about 20cm. Cheers
  15. Untitled

    Untitled

  16. E

    New radiator on one pipe system, is this ok?

    Lol no 10 downing street Make it out to a Mr D Cameron :D
  17. E

    New radiator on one pipe system, is this ok?

    Ok cheers for all your help guys. I'm going to do it tomorrow. I really appreciate your time, it was a silly mistake which would've cost me more than an hour of my time if you hadn't all posted, so thank you!
  18. E

    New radiator on one pipe system, is this ok?

    How About every time I want it to get hot I turn off the inlet valve lool!
  19. E

    New radiator on one pipe system, is this ok?

    If I tee from the main pipe into the horizontal run before the pipe gets to the right valve will that sort it?
  20. E

    New radiator on one pipe system, is this ok?

    So the rad will get hot once then not again. Well the same could be said for any rad on anyone pipe system right?
Back