    boiler problems!!

    I think the OP is confusing 'boiler' with 'cylinder' as a lot of people do.
  2. N

    Noise from airing cupboard

    You'll probably find debris has got into the pump impellor causing it to vibrate. Ask (tell) them to clean or change the pump. You've probably paid enough :cry:
  3. N

    Chaffoteaux Britony Help please

    The primary thermistor will also cause this fault. Overheating.
  4. N

    Working for British Gas these days

    What did happen to 'Fan Lube'? :)
  5. N

    Worcester combi boiler - greenstar 24i junior

    do you mean the burner light is not coming on at all or that the ch is just not working?
  6. N

    Britony combi 80 boiler

    Air pressure switch, flow switches and thermistors.
  7. N

    Stop cock in the street.

    Give em a call, they'll tell you which way or another. Portsmouth Water are normally very good.
  8. N

    worcester 28cdi diverter and expansion vessel

    About 2.5 hrs to change the expansion vessel on a CDi (albeit a nasty job) or 1/2 hour if you've plenty of access to the left hand side of the boiler.
  9. N

    is it asbestos insulation?

    The only way to test if its asbestos is to get it tested in a lab. You can't tell by looking (unless its got 'asbestos' written on it :wink: )
  10. N

    baxi solo 2

    So this must be the r/s version of the Solo2 rather than the FF that we're all thinking of. :wink:
  11. N

    Heat exchanger for Baxi Bermuda back boiler.

    Depends which Bermuda? I think most are still available though.
  12. N

    Vaillant DIV valve. DIY job?

    I think the OP has the Turbomax Plus with the motorised div valve and not the mechanical one you're refering to.
  13. N

    Boiler casing holes non-repairable?

    Ultimates are negative pressure.
  14. N

    Leaking Drain Cock on Potterton Kingfisher CF125 Boiler

    Christ almighty, that looks like a piece of ****. Turn it off now :shock:
  15. N

    One for the British Gas lads.

    Still loads of radicals on my patch. If they stop then I'll have to find other employment. Maybe come back as a contractor :wink: :wink:
  16. N

    baxi 100 he

    Thiis boiler is the same as a Promax. Do a search on those, could be any number of faults. Ignition pcb is a common fault as is electrode, combustion seals, condense trap etc......
  17. N

    Worcester 24i Combi Boiler constantly resetting

    You need to check whether the boiler is modulating i.e. the burner pressure is getting lower as the water temp is increasing. This would cause the above fault. Burner pressures need to be checked. But it could be that theres scale in the heat exchanger.
  18. N

    worcester 24i

    Or you could just turn the mains water off :roll: :wink:
  19. N

    worcester 24i

    Never assume............... :wink:
  20. N

    worcester 24i

    The Worcester 24i is a boiler all on its own. The lower entry boiler before the Cdi. Nothing to do with the Junior.