Search results

  1. J

    help with sky surround sound

    Hi, I am having trouble with sound with sky being out of sync.Using plus, connectors not scart,jack connectors, expensive ones, terrestrial is ok.Not o/p.tried dolby/normal settings on the box. I use dvd receiver too. Any help would be very grateful
  2. J

    new veissman

    Hi Transam, That I will do.At present it,s a smashing, very quiet boiler.It,s doing at present what I require. Had circumstances been different, I would probably have chosen Worcester or Valiant,when I changed. However, my friend, the Manager , who was Worcester Engineer for years, before...
  3. J

    new veissman

    Hi Transam, yes , I am here again,If it wasn,t for a safegas Engineer from Homeserve coming out to change a heating manifold diaphragm, and 4 hours later, My boilers kaput because he knackered the main heat exchanger up, none of this would be happening.I,m lucky to have bad luck.I won,t...
  4. J

    new veissman

    Hi MM, I have stated several times the original problem,the boiler shutting down for no apparent reason at 86.2c.I watched it do it on 3 occassions, even on number 1 setting on the central heating.It just crept up and shut down on thermal cut out.I stopped it on the 4th time at 83c using...
  5. J

    new veissman

    Hi simond, I am sorry if I have not put all the commas in the correct place, or some spelling is incorrect. I cannot see what,s hard to understand; It,s the Main GAS pipe the subcontractor for Viessmann has stated as being undersize.I have posted his report which claims he reccomends...
  6. J

    new veissman

    Hi Tony, I believe you are correct.I do not know the actual loss , but I did ask the RGI at time of commissioning, and althouh I cannot hand on heart state it, I am 99% certain it was as I stated, 1.2mb loss.which he probably assumed was not worth renewing pipework for, although, it would take...
  7. J

    new veissman

    I am presuming that was his intention,I cannot think of another logical reason.The RGI and Manager didn,t say why they took it away, it must be Viessmann policy not to give cards out when attending their work.I really don,t know what to think anymore.I haven,t got it now.At the time I didn,t...
  8. J

    new veissman

    Hi Tony, I understand what you say.This is the original report given to me when the RGI commissioned the boiler.As you can see, the figures differ to the other set I supplied.All I know is I was told the loss was within the manufacturers parameters, so pipe upgrade wasn,t nescessary.As regards...
  9. J

    new veissman

    Hi MM,Thanks for your reply.Since my post above, I have received a visit from my RGI,and The sales Manager from Veissman, who happens to be a personal friend, time served gas engineer, knows what he,s talking about.He did a thourough check of installation,pressures, cold water temp, hot water...
  10. J

    new veissman

    Hi MickyG, thanks for reply,and Tony, much appreciated.The Engineer had the hot tap on full whilst running boiler.He checked the meter pressure and even boasted how he could do all his conversions using a mobile phone,he then checked it at boiler using flexi pipe, rubber, at top front of...
  11. J

    new veissman

    I Hope this is right.
  12. J

    new veissman

    any hints on posting copy?[/img] :?:
  13. J

    new veissman

    Hi Mickyg, doesn,t boiler size come into the equation?
  14. J

    new veissman

    Hi Tony, if I can I will post them,if you tell me how.What if the second reading is the right one<18.5mb, should it still work correct, and working correct, does it mean I should get 30kw,not 22 as he stated?cheers .I,ll try and post his sheets,
  15. J

    new veissman

    Hi Everone, Thanks for replies, I,m no stranger to this site, hence my questions.Firtsly, I didn,t call the Engineer, the Installer did, he is Veissmans RGI, my mate is their Area sales manager/ex worcester/veismann engineer.I had a straight boiler swap because a certain breakdown company came...
  16. J

    new veissman

    Thanks Tony, I quote Engineers report.AIWP.18.5mb.gas rate or burner pressure or combustion reading.22.84kw gross.Gas rated boiler.@22kw gross.Advised new 25/28mm supply.Told Installer,awaiting a replyThe Engineer has left 5 sheets of reports.My white says AIWP.18.5mb.The...
  17. J

    new veissman

    Sorry;;,he said 10kw reduction.That,s why I am so confused at such a big anomoly.10% wouldn,t have bothered me.
  18. J

    new veissman

    Hi Tony, Just confused at why Engineer says 25mm needed, yet installer told me 22mm was ok.Both took water temps and pressure at Max at meter and boiler.Engineer says water should be 10 degrees higher on max.50 not 40.Will 25mm be beneficial or not?