Search results

  1. M

    Laminate Flooring on an inset step

    Hello Any advice on how to use laminate flooring on a inset step in this case from a dining room into the kitchen? Ive watched numerous videos on stairs but this is somewhat different. Thank you
  2. M

    Potterton Suprima Repeated Lock Out....

    Hi Andy Yes the pump is running as before
  3. M

    Potterton Suprima Repeated Lock Out....

    I have a Potterton Suprima 80 boiler which has starting locking out every two minutes... The boiler has a new PCB and overheat thermostat fitted (a new second spare pcb has also been swapped in and the same issue remains) It fires up from the timer on both the CH and DHW timings but after two...
  4. M

    Remeha Avanta 28C PRV Issue

    Hi Stuckinarut, you were correct - the expansion vessel isnt holding pressure. I left the guage attached for a good 30 mins and it was at zero. Ill get a new vessel and see what next to rule out ...
  5. M

    Remeha Avanta 28C PRV Issue

    I did, so it points towards the expansion vessel then. I guess its not unheard of that a new PRV can fail but highly improbable... Ill be back on friday and pick up where I left off. Thank you very much for you time and thoughts thus far
  6. M

    Remeha Avanta 28C PRV Issue

    I will check the pressure again on Friday when Im back at the house and see - maybe it tell a different story by then.
  7. M

    Remeha Avanta 28C PRV Issue

    correct a bicycle foot pump
  8. M

    Remeha Avanta 28C PRV Issue

    Hello and thanks for the reply, I changed it as the boiler had been sitting unused for several months and when last used the dripping was occuring. When I took the old one off it was totally crudded up so seemed like the correct approach. I topped up the expansion vessel to 1 bar and 24 hours...
  9. M

    Remeha Avanta 28C PRV Issue

    Hello, I have replaced the PRV in my Remeha Avanta 28c last week and noticed a slight drop in pressure despite the PRV being new. The heating circuit and radiators are watertight having been tested. I placed a receptacle under the exterior pipe on the outside wall and it has collected about...
  10. M

    Deep shower waste trap advice

    In my case there simply isn’t enough clearance to get a grip on the locking ring as it’s not clear of the actual flooring which is the issue the original poster had too
  11. M

    Deep shower waste trap advice

    Just an update, Not enough access to get the pipe/Spigot so Vertical trap was the correct solution
  12. M

    Deep shower waste trap advice

    Glad it was successful, I’ll try the same
  13. M

    Deep shower waste trap advice

    Hi Kinhell What solution did you come up with in the end? I have exactly the same problem in a loft conversion. Infact I’m amazed more people haven’t encountered the identical issue with a standard flooring being 18mm and the recommended cement bed as you’ve stated …
  14. M

    Pyronix Enforcer

    Just an update to say the front door sensor is now working in unison with the control panel once again. Many thanks for the advice, suggestions and general help clearly I had confused the system previously in how I added the sensor .... Appreciate it.
  15. M

    Pyronix Enforcer

    Definitely learned to Final Exit being the front door but I will check again tomorrow to be doubly certain. Handymanjo I’ll try making zone one unused as you suggest and see if that does indeed clear the error … will try tomorrow as I dont want risking the alarm going off in error tonight
  16. M

    Pyronix Enforcer

    I’ve tried it with A, A&B and it’s still coming up with mismatch …
  17. M

    Pyronix Enforcer

    HandyManjo, Josh - when you say 'ZONE TYPE' is that A and B Input Areas ? is that the same thing?
  18. M

    Pyronix Enforcer

    Still tearing my hair out ... this is the process Ive followed : Deleted and then Added the door sensor - its saying Learnt Then Change Inputs Input (01) Front Door Input Type (07) Final Exit Input Areas (A,B) Input Areas (0) ANY Input Attributes? Chime No Omitable No Double Knock No...
  19. M

    Pyronix Enforcer

    Ok, I’ll follow your idea and see where that takes me
  20. M

    Pyronix Enforcer

    Many thanks for the reply. Yes I’ve re learnt the device to both Zones A & B which is why I’m concerned it doesn’t work so far
Back