    Stuart Turner Monsoon 2.0 Twin - Humming

    Have that in place already and will give it a close looking over in the morning after the showers been run
  2. M

    Stuart Turner Monsoon 2.0 Twin - Humming

    Problem solved! Decided to take the cover off the opposite side and surprisingly the Impeller was rotating freely, so tried the original side again and it too was now free. Put back together and powered it up and again just the humming, so I figured maybe it was basically overtightened so I...
  3. M

    Stuart Turner Monsoon 2.0 Twin - Humming

    Just plumbed in a Stuart Turner 2bar twin unit having been sat unused for several months. All Im getting is a humming from the motor nothing else. Ive read its either, Start capacitor, PCB or most likely a stuck pump. The suggestion is to rotate the pump shaft. I assume this is the shaft onto...
  4. M

    Potterton Suprima 80 Airlock

    Ill keep an eye on it for now but thanks for all you time and advice, if it goes wrong again in theory i know where the problem is. Its a very awkward set up indeed, and been told also that the pump should be rotated through 90 degrees as its currently in upside down... and its been plumbed into...
  5. M

    Potterton Suprima 80 Airlock

    Managed to get a pic of the top of each, I assume they should be identical spec units as I'll order replacements? Wont do any harm to replace both at least I'll know the history from here on. Will have to drain the system down again to fit three more new rads in a day or two - Im dreading the...
  6. M

    Potterton Suprima 80 Airlock

    Bit of good news! I rocked the levers on both port valves rapidly and tapped both units several times and Hey Presto the green light comes on and she's fired up! Also no air lock is apparent seems to be running smoothly. Went to the cylinder and can hear the water boiling in the tank. So one...
  7. M

    Potterton Suprima 80 Airlock

    Hi, The only DHW is whats left from the last time the HW circuit was working - Sunday night. The two port valves are HoneyWell pics attached and yes the one on the left feels like two settings on the lever and the on the right it feels like three options - cant see the tops... Cylinder...
  8. M

    Potterton Suprima 80 Airlock

    Hi Terry, the gremlins persist. The HW call on the timer had and still has no response from the boiler, it sits in standby with the orange light illuminated. The CH fired up off the timer and still works fine. Leaving the PCB as the last option, could there be a problem with the zone valve...
  9. M

    Potterton Suprima 80 Airlock

    Thanks a million for your time and your thoughts, appreciate it. Ill keep an eye on it and see if it corrects itself fully by morning and I'll update you tomorrow. Thanks again Terry
  10. M

    Potterton Suprima 80 Airlock

    Kind of, when I call for HW theres still a lot of gurgling water around the boiler/pump pipework and then it returns to standby so wont stay on
  11. M

    Potterton Suprima 80 Airlock

    Theres hot water but how much Im not sure - I'll find out in the morning I guess
  12. M

    Potterton Suprima 80 Airlock

    Above that Flow marker is the valve from the F&E Tank into the system
  13. M

    Potterton Suprima 80 Airlock

    Its connected to the return pipe at the base of the coil. I'll change that out for a proper bleed valve, still getting my head the plumbing in this place... Yes, Ive hit the 'boost' button for hot water, it fires up then goes back to standby mode after a minute or two leaving the Boost light...
  14. M

    Potterton Suprima 80 Airlock

    Its connected to the return pipe at the base of the coil. I'll change that out for a proper bleed valve, still getting my head the plumbing in this place... Yes, Ive hit the 'boost' button for hot water, it fires up then goes back to standby mode after a minute or two leaving the Boost light...
  15. M

    Potterton Suprima 80 Airlock

    I opened it just now and no air just spewing steaming hot water
  16. M

    Potterton Suprima 80 Airlock

    I'll get a couple of pics now and Maybe you would suggest changing it for a more usable air bleed
  17. M

    Potterton Suprima 80 Airlock

    Got a pic of the pump with the slot as you mentioned. Good to know it exists. So it's therefore the HW circuit thats the issue. If that bleed point on the flow/return (coil) circuit isn't expelling any air worth talking about would it therefore suggest theres possibly insufficient water in that...
  18. M

    Potterton Suprima 80 Airlock

    Why would the pump not bang and thump on the when the heating is on ? They are two different circuits but how does the primary circuit carry the airlock when the heating circuit doesnt ?
  19. M

    Potterton Suprima 80 Airlock

    Sorry, Yes the central heating is working ... now! It starting heating then went into a standby mode so just left it and then heard gurgling from the living room radiator so I went around bleeding the radiators again and it began working again as normal
  20. M

    Potterton Suprima 80 Airlock

    ok - just as well as that red valve would only be reachable with someone with the arms of Mr Tickle! I can feel a slot on the top side of the pump so Ill try to get a pic and confirm with you if that looks like a bleed point