Search results

  1. H

    wiring for a conservatory

    hi, The company are sending a spark tommorrow to sort out my wiring. Now my question is: Will he have to conect the cables at the back of the socket using ratchet crimps and crimp connector or can he use chocolate block connectors (the clear/black screw connectors) Thanks everyone who has...
  2. H

    wiring for a conservatory

    cheers adam! So was I right???????????? COWBOY or am i an ASS
  3. H

    wiring for a conservatory

    cheers.i have emailed you the infamous picture
  4. H

    wiring for a conservatory

    Yeah i have been speaking to the "builder" who completed the work. I think hes just trying the bullying tactic. I have sent an email to my LABC with a picture. See what happens! Cant get the photo on here though....dont know how to?
  5. H

    wiring for a conservatory

    just got home and checked socket again, the builder said he had crimped the two wires at the back of the socket, im scared i am making an ass of myself here. To clarify there are no crimps. what i have is as follows: the original two cables going into the terminals of the socket ( the original...
  6. H

    wiring for a conservatory

    Just spoke to the builder and hes quite upset at me questioning his work......he said he has wired it as a ring and if I know what im talking about then do a "loop impedance test" as he has done to prove it.....is this right what is the purpose of a loop impedance test
  7. H

    does part p apply to a new conservatory???

    ive just been in contact to the bc officer, and he has said as of yet they are not getting involved with conservatories, only wet areas! ie kitchen and bathrooms. Ive read all about part p and it seems very ambiguous to say the least. The ultimate responsiblitiy is with the customer however i...
  8. H

    does part p apply to a new conservatory???

    who are doing what against the law? the bc or the conservatory company. Also if I get the bc to check wont this cost me
  9. H

    does part p apply to a new conservatory???

    yes i live in manchester! should the conservatory company know this? and should they be registered
  10. H

    does part p apply to a new conservatory???

    do i need to get a qualified part p electrician to install my electrics on a conservatory??
  11. H

    wiring for a conservatory

    also how does this apply to "part P". should I get a certificate after installation is that what part p is essentially? ++++++++++++++++++++++++++++= I have just checked the socket again! I have 4 live wires going into the live connection of the socket.These are 1 from the feed,1 going...
  12. H

    wiring for a conservatory

    no he has definately put the ring of the conservatory into 1 socket. the socket now has four wires (4 lives and neutrals etc) the socket next to 1 in question is still fed from this socket!
  13. H

    wiring for a conservatory

    the original guy was definately a spark (saw his van etc) however he was on holiday this week and the conservatory company are on notice to get the conservatory finished by friday! So the guy who did it is a builder who said he can do electrics!!!!!!! If hes not a spark can i report the...
  14. H

    wiring for a conservatory

    is it safe? or should i disconnect it while i wait for a spark?
  15. H

    wiring for a conservatory

    Can someone advise me! I have just had my conservatory fitted and the electrician fitted 4 double sockets and 2 fused spurs( 1 for a outside socket 13amp to a mk waterproof socket and the other a RCD fused spur for my underfloor heating this will be 10 amps). He did this as a ring, leaving the...
Back