  1. H

    Baxi 552 Banging

    Sounds like kettling to me..............
  2. H

    Is this quote reasonable?

    This gets worse!!! £9200 + Vat a month.£110,400 a year!Im self employed and have running costs but jesus my cost dont invole a new Van every 2 months!! Talk me through what costs you have over myself to warrent £110,000 a year per man salary?! Way Way over the top, particually in this...
  3. H

    Is this quote reasonable?

    Christ!! £6900 + VAT a month!! £82800 a year!!! Thats some plumbing money! Lets be honest, were plumbers and not Doctors here!!!!!
  4. H

    sabre

    Ive fitted one of two Vokera compacts which are the same boiler and have had no bother with them in the 4 years they have been in. Not the most advanced boiler, but unlike Agile, i'd have one over a Biasi or a Heatline!! Youll get a different opinion from every installer. Just make...
  5. H

    Vaillant vs. Baxi

    The two boilers really cannot be compared as they are not alike. The 937 looks like a washing machine hung on a wall and takes up about as much space, but the hot water performance is very impressive. The Baxi is a standard combi which in my opinion is exceptionally well built and great...
  6. H

    Sabre 24

    No mention of it being the 24he Paul. The sabre 24 was indeed a Vokera compact 24 but with a different pressure gauge. It has a twin pass heat exchanger. Not a divertor valve in sight on this model.
  7. H

    Which Boiler??

    Vaillant are over priced, over engineered, over complicated, and over modified and thus unrelliable in my opinion. Cheap components selling at a premium price. ATAG are good top spec boilers, Viessman are good mid range and Baxi are a cheap, better made vaillant (with a decent pump!) and are...
  8. H

    Worcester not providing warranty if boiler installed in loft

    Do you not agree on the Ecomax though...now that was a boiler!!!
  9. H

    Worcester not providing warranty if boiler installed in loft

    Price is one Pre piping jig is two Simplicity is three Grundfos pump is four Cheap spares is five......................
  10. H

    Worcester not providing warranty if boiler installed in loft

    He says with hose pipe for arms!!! Yes ive seen the ecoteq.........and seen the plasitic naff they call pipe connections to the main heat ex. And the pointless PCB/display they use where you can control it down to how many times it passes wind in an hour. Yes ive replaced the hoses when they...
  11. H

    Worcester not providing warranty if boiler installed in loft

    Im installing a lot of baxi duotec boilers at the mo..........cheaper boilers built better than most counterparts. The boiler is 90% brass too not like these Vailant and Worcseter plastic city counterparts that spring leaks at every given oppotunity. heat Team are a great warranty group too...
  12. H

    Class bit of work

    Not good but it must have worked for a few years fine?
  13. H

    Vaillant boiler leak

    Had to change the div valve on my mothers Vaillant 2 weeks ago for this reason. I have a freinds who is a Vailliant/Hepworth engineer and he says it is becoming a particular weak point on vailliants that use this valve.
  14. H

    Main Medway Super Water Heater

    Lets hope your daughter has a nice first house to come back to next time she goes out..............
  15. H

    Vokera compact 28

    Isnt the filter on these on the left hand side of the plastic manifold. Held in on an oring and a clip?
  16. H

    W-B 37CDI

    Are they so 'intelugunt' that they cannot spell intelligent correctly?
  17. H

    Boiler Service

    To check the gas valve, justattach your manometer to the inlet test point, run appliance, isolate gas. You can then check to see if the gas valve is paasing by carrying out a small let by check of the gas valve byt testing between the appliance isolation valve and the gas valve outlet. Lot...
  18. H

    Boiler Service

    You really are looking for earth bonding too much. On a service visit the only place you need check is the gas meter! By 'UnVented 'System most would presume your refering to the DHW. The terminology used by manufacturers and publications is 'sealed' system when refering to central heating...
  19. H

    Boiler Service

    Since when has a tightness test been part of a standard boiler service????!!! Spotting pipework not bonded is hardly going to take up more than 1 second of your '1 hour super service'. You really need to work a little harder if your taking 1 hour to serive a boiler such as this. Id...