Search results

  1. W

    Problems with my S plan Heating system - Microbore pipes etc

    Do you not actually have a cold feed into the system??? (from the bottom header tank into the system)
  2. W

    Problems with my S plan Heating system - Microbore pipes etc

    I mean the gate valves, again where is the cold feed an vent??? if not directly on the boiler then by isolating all those gate valves and running the boiler will result in a bang as nowhere for expansion, we still have only half the picture, to get to the bottom of your problems we need to...
  3. W

    Problems with my S plan Heating system - Microbore pipes etc

    Something to be careful of.... do not run your boiler with all those gate valves turned off....... boom!!
  4. W

    Problems with my S plan Heating system - Microbore pipes etc

    ok where is your cold feed and vent?? if not already you may be better to convert to a sealed system,
  5. W

    Problems with my S plan Heating system - Microbore pipes etc

    As said before we need some pictures to sus whats been done right/wrong, boiler, airing cupboard, wiring etc............... You said you fitted a zone valve on the boiler flow - is this directly off the boiler??? does your h/w zone valve tee off before or after this valve on the flow...
  6. W

    Feed And Expansion Tank Loosing Water?

    'isolated the vent pipe' what ever you do do not cap off the vent pipe!! you shoulnt have anything come out of the vent pipe off the h/w cylinder anyway regardless of split coils and heights of tanks,
  7. W

    Feed And Expansion Tank Loosing Water?

    If you h/w cylinder coil has gone then your f&e tank would overflow - not lose water, you did say both tanks are on the same level base didnt you??? so the cws water level will be the higher. I wouldnt think its the coil personally.
  8. W

    Riello Hydraulic Jack replacement

    You can i think still get replacment seals for the oil rams
  9. W

    Find a Leak.

    If you are loosing pressure its not the hot water exchanger as this would increase pressure, prv letting by???? check to see if discharge pipe is wet outside, if you are sure there are no leaks on the system then it must be the boiler. you can run the boiler for dhw with the heating circuit...
  10. W

    Feed And Expansion Tank Loosing Water?

    Has your f&e tank got a lid?? if youve left the cold main to the tank off you could be loosing a bit through evaporation, especially if theres a problem with pumping over the vent as the water will be hot.... just a thought,
  11. W

    Toilet glug and vibration due to new loft conversion?

    Is there a vent on the new soil pipe up in the attic?? sound like when you are draining your bath is creating a vacume in the soil pipe pulling out the water in the toilet u bend,
  12. W

    Feed And Expansion Tank Loosing Water?

    If your coil has gone in your cylinder the lower of the tanks will overflow, normally the f&e tank is lower so a cracked coil will result in the f&e tank to overflow, have you got any under floor pipework???
  13. W

    oil boiler shuts down after about 10 mins

    cant really see a problem, if you say everything is getting hot and boiler is shutting down on boiler stat thats norm, i take it you dont mean overheat stat - are you having to press the reset to get the boiler on again???
  14. W

    3 port problem

    In order to get 230v on the orange wire when valve opens you must have 230v on the grey wire (either from h/w off on clock or cyl stat satisfied)
  15. W

    Unidentified pipes/Pumped Combi

    Do you know if the flats used to have communal heating??? could be the old primarys of a fortic / elson tank,
  16. W

    oil burner problems

    Exactly what is happening when you reset it the first few times???
  17. W

    Oil Heatslave Pressure problem

    Hi, i take it when you have checked the vessell pressure there was no system pressure and the prv was open?? also check the braided line to the vessell is not kinked.
  18. W

    Advice on power shower.

    The shower i will be fitting will be a reasonably cheap (£100ish) bar mixer with a 3 pattern head, i had planned on fitting a watermill 3 bar pump an now 22mm pipe work right through. The only thing im not sure about is the size/location of the header tank.
  19. W

    Advice on power shower.

    Hi, ive got to install a new mixer shower and pump but i dont normally get too involved in this kind of work so need a bit of advice...... going to fit the pump in a/c but the shower will be a good 25m run away, (with pipework runnig through the loft) what pump would be best for the long run and...