  1. H

    PRV change

    If as picture suggests check vessel pressure,,,,,depressurized. Plus is old valve full of XXXX. If so will only happen again ,,,,so cleanse
  2. H

    Glow worm Flexicom 30CX Error code F4

    Lashings of hot water :D
  3. H

    Vailant VCW GB 242e Boiler Not hot water

    From your post i was assuming all was fine but water has started to cool over a period of time with the same flow rate. As the other posts are correct on flow rates
  4. H

    Vailant VCW GB 242e Boiler Not hot water

    Possible low burner pressure, you need an engineer as these valves do get out of calibration. There was a Vaillant excersise on valve replacement quite some years ago but only done on open flues as i remember. You need a guy who is aware how to set these valves. Or as i get alot in my district...
  5. H

    Vaillant vcw 18 t3wf h

    To be quite frank ,yes a very good boiler in it's DAY. So was the Ford Sierra a great car in it's day, get my drift. Also if it is a balanced flue you can bet the flue seal has failed on it by now,,,,not good.
  6. H

    Glowworm 30cxi pressure drops

    Expansion vessel pressure should be checked depressurized and only be usually as rule of thumb 0.7/0.9 bar. As previous thread said vessel could be ok but supply tube to it could be blocked, all be it rare but very much worth checking.
  7. H

    How do get my water hotter

    I would go with the first post. Saunier Duval have now withdrawn from the British market and any support and parts will be close to follow.
  8. H

    Worcester 24CDi combi boiler pressure gauge

    Plastic knob on plastic spindle. Notorious for just spinning on the spindle. Knob should have flat edge to marry up with flat edge on spindle, bet the spindle is rounded off in which case a pair of pliers for now to turn off filling loop, ultimately you need a new filling loop kit.
  9. H

    britsh gas f'''ers!!

    Forum used for b/g bashing, how predictable. Do not forget we only have one side of the story. Ex-employee by the way, but when will this site stop being used to trash people and be used for it's proper purpose. This would not have been a post if it would have been Joe Bloggs the plumber,, no...
  10. H

    Sime Friendly hot water problem

    Diverter valve is passing to the heating,,as we say. Basically means not all the heat energy generated by the main heat exchanger is being transfered to the seconary heat exchanger(hot water exchanger) and most of the energy is escaping to the hting circuit. Sometimes a full service kit on the...
  11. H

    Career in plumbing

    British Gas offer good training and salary packages with perks, but they expect alot. You are measured on everything and if you dont perform then you are dragged into a whole world of hell. It is very stressfull at B/G these days but if you like stress then great.
  12. H

    Do i buy a MagnaClean Central Heating Cleaner?

    Would not drive your car without an oil filter would you. Why should a c/h system be different has xxxx floating about in it.
  13. H

    Frozen condensate pipe....

    Extreme temps i am afraid. Even had the large diameter pipes with a perfect drop freeze. What do you do,,,you fit to manufacture spec. Is this a one off winter or is it signs of things to come if so everyone will have to rethink condensate routes, not just British Gas everyone is suseptible.
  14. H

    baxi boston

    Hey, Usually a contributor but need help with something i have never tackled. Baxi Boston h/ex leaking via the seals between the h/ex sections. My question is has anyone out there tackled one of these. My company wants me to change the section seals but how does the damn thing come out. Looks...
  15. H

    Ideal Icos HE18 Boiler

    Sick of pcb and fan faults on these boilers,,,,ideal STOP MAKING THEM!!!!
  16. H

    Glow-worm Ascot 1.4S

    Ascot 1.4s sorry agree with B/gas guy you need to replace,,,,sorry
  17. H

    Please help - boiler running but rads not warming!

    yeah you may look into the small window and see a small pilot light,alight but is the main burner on,,,,sounds to me as thought the boiler is not rectifying,,,,you need an engineer all said and done. If the burner was on and the pump had failed it would overheat and something would feel hot and...
  18. H

    British Gas asking for money!!

    B/gas are probably priced higher than most but end of the day they guarantee the flush for life, magnaclean are good and worth it. Used to do flushes for B/G and they were done properly with few come backs and that is what you want. If i do a job now and B/G have flushed it i am happy. You get...
  19. H

    ideal 30he isar

    yes avoid it