  1. E

    New Vaillant system boiler & cylinder installed

    Bet you feel so smug right now. :LOL::LOL::LOL: Problem is idiot like you (y)
  2. E

    New Vaillant system boiler & cylinder installed

    Well looking at the pictures your right hand fused switch that does your immersion has LNE crossing to the spur for the heating. Yet you have a L&N that looks like it goes to the cylinder stat that controls a critical part of the safety group . Guess why your hot water ain’t working. Guess it’s...
  3. E

    New Vaillant system boiler & cylinder installed

    Cold feed is well clipped !! . Guessing old cylinder cupboard and they have now spurred of the old dedicated immersion feed. If it was dedicated to the main fuse board that is. Be interesting how they terminate the d2. Foam around flue says it all really.
  4. E

    New Vaillant system boiler & cylinder installed

    What planet you live on. You think the wiring is ok then go specsavers. Someone said it’s ok to be shoddy but long as it works. What a laugh. Besides a critical d2 component missing then great the workmanship, top notch. Feck me there is some halfwits on here
  5. E

    Plan for Revised Heating Plumbing - Appreciate any feedback

    Ps most boilers flow is on the left.
  6. E

    New Vaillant system boiler & cylinder installed

    True but when they work they are as simple as can be.
  7. E

    New Vaillant system boiler & cylinder installed

    Shame as the the st699 was a simple but good programmer. But a new install should be upgraded to comply.
  8. E

    New Vaillant system boiler & cylinder installed

    Hopefully the 2 port to the cylinder is via the overheat stat. But if by the pics and wiring I’d get it checked also. Like I said seen worse but it’s not good
  9. E

    Replace Brittony 11T will save gas ?

    Rinnai as mentioned made a water heater to replace said water heater. Done a few. Iv been using rinnai for years on campsite toilet and shower blocks etc. Iv used the domestic one in restaurants and they are great bits of kit. Most reliable water heater Iv come across
  10. E

    New Vaillant system boiler & cylinder installed

    Also prv on the combination valve. That will need looking at I guess
  11. E

    HEP2o or John Guest for plastic fitting

    Personally hep is the best. Use both but if budget is tight then speedfit. Find the roll flat speedfit is what you would get normally with hep
  12. E

    New Vaillant system boiler & cylinder installed

    Combination valve I would put above cylinder, otherwise drain down to replace etc. wiring is crap. D2 pipe terminates where? Seen worse though.
  13. E

    Fit a Remote Expansion Vessel

    Ps mr combi is a tool. Not many combi/system boilers are connected with 22mm/3/4” connections with there internal ev. Most are 3/8th .An external ev can happily have an isolation to it. There’s purpose valves for this...
  14. E

    Problem with pressure reducing valve?

    Cylinder made by McDonald engineering by any chance? They would use low prv and group set. The ev could be acting as an accumulator. Needs to be looked at by someone that knows what there doing as mentioned. Pretty basic stuff to be honest.
  15. E

    Viessman any good

    Why is it , please explain. Seems you know the job. You had a look at the job? Personally I haven’t seen the job but giving advice as to why maybe the installer could be specifying what boiler. Yourself are just trying to look like mr big *******s without knowing all the facts.
  16. E

    Viessman any good

    https://www.gledhill.net/uploads/Gledhill-Vented-Installer-brochure-2019-v11.6-WEB.pdf Look at the kw rating on these standard cylinders. Page 10.
  17. E

    Viessman any good

    No it can be range rated to your system.