Search results

  1. B

    biasi 24s Diverter Valve service kit

    I was referring to the Biasi Riva m90e 24s gc 47-970-17 ! It has a spring with a smaller diameter one end than the other.
  2. B

    Do i need this watertank with a combi?

    Is it being heated? Before you do anything you need to work out why it is there. If you discover that it is required for some reason you won't be able to move it to the loft, it needs a cold water cistern to feed it from above and the easiest way to do this is from the floor above.
  3. B

    biasi 24s Diverter Valve service kit

    Not a Biasi riva 24s then?!!
  4. B

    Central heating "Thump", Help!

    You're convinced it's the pump, you can change the pump yourself!
  5. B

    biasi 24s Diverter Valve service kit

    The spring that 'pushes' the pin out is not the one on the spindle assembly. You should have received a cone shaped spring as well. No. As long as the spindle is smooth and clean and this assembly looks in tact then it should be as it was manufactured, and work. Your kit should contain 2...
  6. B

    Grumfos Pump seem on constantly

    Hot water cylinder stat. Check stats with programmer switched on!
  7. B

    Grumfos Pump seem on constantly

    Does the pump keep running with the prog switched to off? Does turning room and cul stats down have any effect?
  8. B

    Grumfos Pump seem on constantly

    Depending on valve type you may be able to replace just the electric part. Is it a Honeywell valve?
  9. B

    Grumfos Pump seem on constantly

    Suspect valve microswitch is sticking and keeping live on orange wire
  10. B

    Radiators not getting warm.

    Are 2 of these pipes a larger diameter than the other 2?
  11. B

    Radiators not getting warm.

    Just so's you know; that's an electrical junction box.
  12. B

    Shower pump question.

    Yes, I should have said most installation manuals say 2m min head. I think it's fair to say, as you effectively point out, that placing a pump on the same surface as the water supply would be fine.
  13. B

    Shower pump question.

    They normally require a 2m min head but I've seen them working perfectly well with as little as about 750mm. Bear in mind head is measured to the surface of the stored water.
  14. B

    calculating how much water is in a system

    Work out how many Kw your system is and allow 8 litres per Kw, as a rough guide at least.
  15. B

    glow worm 30 cxi fan problem

    You can certainly remove the PHE and flush it through. Again, instructions for this are in the manual.
  16. B

    Testing the ph (and other nasties) in central heating system

    You can do it by post for 25/30 quid - if you really feel like it!
  17. B

    Twin pump: Alter HWC pipework or fit flange?

    I earlier incorrectly said that the cold pump feed should be above the cold feed to the HWC. To clarify: Cold pump feed should be BELOW HWC cold feed - apologies for this. Particularly annoying as it was only 2 weeks ago I last installed a shower pump :oops: Correctly I might add!!
  18. B

    Twin pump: Alter HWC pipework or fit flange?

    Ok, sorry didn't read your OP properly! So you're pumping all hot outlets?? There could be some reduction in performance if you use more than one outlet at once but otherwise the warix/surrey flange should be fine - at least you won't be dragging air. You could fit a 28mm essex flange but this...
  19. B

    Twin pump: Alter HWC pipework or fit flange?

    Why the 'but'? This type of flange (warix/surrey) is an easy way of installing a pump with an air free connection, as is required. The cold feed connection should be inserted into the cold tank BELOW the level of the cold feed to the HWC.
  20. B

    Glowworm Bolier F9 Fault

    F9 is a rather generic fault code in many cases so although loosely related to pressure/circulation it could be indicating the onset of diverter valve breakdown. If you can, remove the DV, disassemble and clean it, lubricate with silicone grease, reassemble and replace. I have also seen F9...
Back
Top