Search results

  1. xdrive

    Rewire specifications

    I read it online. Part m I think. It says that sockets need to be 350mm from corners. I think that's because a person in a wheelchair would struggle to use in sockets close to corner. I am thinking of putting socket underneath switch so want them to line up. The door frame and wall make a...
  2. xdrive

    Rewire specifications

    I know that. I want to do it according to regs (even though they don't apply). It's for future proofing. Anyhow does a switch or socket have to be 350mm from front door as in photo above?
  3. xdrive

    Rewire specifications

    Not talking about safe zones. Do switches and sockets have to be 350mm from a corner with current regs? I am going to have it wired with current regs. Thinking about it I prefer the heights of the switches and sockets.
  4. xdrive

    Rewire specifications

    I have decided to have them set at current regs. I'll be doing the chasing myself. Would entering the property be considered a corner? For light switches I have gone with 150mm from architrave. But would I have to fit it at 350mm for switch at front enterance if considered a corner? Cheers
  5. xdrive

    Rewire specifications

    Hi. I'm having the whole house rewired. It's had a dormer extension. Do the sockets have to be at height of 45cm and light switches at 120cm?
  6. xdrive

    Make good floor after chimney removal

    Yeah will remove concrete and add timber joists and floor. Dont want cold spots. Edit. Just ripped the concrete off. Lots of rubble. The joists are at the front of chimney. What's best way going about it
  7. xdrive

    Make good floor after chimney removal

    Hi. How can I make this floor good. Do I concrete on top or remove bricks and add joists? Cheers
  8. xdrive

    New windows

    Hi. I'm thinking of having new uPVC windows. Under the old windows they are sitting on a piece of timber 2cm thick. Is it best to remove timber for new windows to sit directly on brickwork? Will sit on sill. Or is it better to have timber under sill? Cheers
  9. xdrive

    Anyone who can draw plans to building regs......

    This old thread made me chuckle :rolleyes:
  10. xdrive

    Blocking up air vents in bedroom

    @stem that makes sense. I was also thinking the channel would be visible other way around which doesn't look pleasing and more chance of flys getting in. It's an extra bathroom so won't be used much and there's a window also. Will keep it way it is for now. Cheers mate
  11. xdrive

    Blocking up air vents in bedroom

    has this vent been installed correctly? The grille are facing towards dormer.
  12. xdrive

    Blocking up air vents in bedroom

    Decided to keep them. Just need to get nice air bricks for exterior. Cheers
  13. xdrive

    Blocking up air vents in bedroom

    Hi. Thanks for response. It's a cavity wall filled with insulation. The small bedroom one was rendered over. I know ventilation is important but the size is too big. Two bricks high. Is there any other reason for the vents like allowing air to cavity? I know many houses get mold because...
  14. xdrive

    Blocking up air vents in bedroom

    Hi. I have some ugly airv in my 3 bed semi . They are in the box room and one bedroom. Also one in bathroom which I will use for a fan. There are no gas fires and chimney breasts and chimney stack removed. I've removed the metal grills as they have rusted and I'm about to brick up. I see new...
  15. xdrive

    Question on render

    Right. What about the coloured render. Is 10mm ok or same apply? He said thin coat is better as thick tends to crack
  16. xdrive

    Question on render

    Can you go over the beads so you get 13mm as they only had 15 and 10mm beads
  17. xdrive

    Question on render

    Right the render is finally off. Pain in backside. I had somebody come to have a look. For sand and cement recommended 10mm beads. Is this right? Seems a bit small.
  18. xdrive

    Cutting lead flashing

    Right I'm pretty confident doing this now. Is 15 to 20mm in brick sufficient? Then will use rolled up lead and point with lead sealant. Finally will apply patination oil.
  19. xdrive

    Cutting lead flashing

    Hi. Im doing lead flashing on porch. It's around 5.5m long. Using 9 inch code 4. What's best way to cut it. Don't have any special cutters. Have a Stanley knife. I know max length of flashing is 1.5m. is 100mm overlap ok (can seal with lead sealant). Don't want to buy another roll...
  20. xdrive

    Question on render

    Hi. I've decided to get all of it rendered as per your advice. I'm removing old render with sds. Would I have to go back to brick? As the base coat is on really well. The top pebble dashing comes off easily enough. Thanks
Back