    2 Google Nest Thermostats for 2 zones connected to Intergas Rapid 32kw

    Hi, I would like to connect 2 Google Nest Thermostats for 2 zones to an Intergas Rapid 32kw (used as a combi boiler). Below is the wiring for the Nest as provided by Google: Page 63 of the Intergas Rapid 32kw manual shows that the Live and Neutral are on pins 2 and 4 of the X2 connector...
  2. A

    Using lever ball valve as draining valve.

    Sorry I should have replied, the house is split into 2 parts, the front and the back (i.e. an extension) with a thick wall between those. The easily accessible part is the front, unfortunately I cannot drill through the front façade as it is a listed building. Also I exactly identified the...
  3. A

    Using lever ball valve as draining valve.

    All those conditions are met, thanks!
  4. A

    Using lever ball valve as draining valve.

    Sorry this is a typo from myself, I am definitely referring to the second one, i.e. the Lever one and not Level. Glad to know it can be left in a closed position and not loose any pressure.
  5. A

    Using lever ball valve as draining valve.

    This is because it is underneath a Victorian house in the crawl space and I only have access to 40mm waste pipe to drain (it would be hard to drill a hole in a 40cm hole, and since it is listed I cannot anyway). The easiest way I found to drain from 22mm to 40mm waste is by: 1) Using a 22mm tee...
  6. A

    Using lever ball valve as draining valve.

    Hi all, I am installing all the pipes for a new CH system, the lowest point is 1.5m under the floorboards which I have access to. For convenience I would like to use a 22mm lever ball valve as my draining valve (I am planning to purchase a full bore one) which I will connect to a 40mm waste...
  7. A

    Opentherm on 2 zones installation

    The ground floor of the house is the main living area (living room, kitchen, office) and the first floor is for the bedrooms; it would make sense to split the CH into 2 zones as the first floor is not used that much during daytime.
  8. A

    Opentherm on 2 zones installation

    Thanks, so I should be able to use opentherm on 2 zones independently using those 2 Honeywell thermostats (instead of my 2 Google Nest thermostats) with 2 zone valves, is that correct? It is a bit annoying I cannot use my Google Nest thermostats for multizone & opentherm... Regarding the...
  9. A

    Opentherm on 2 zones installation

    Hi all, I am about to get a new Intergas Rapid 32 Plus boiler installed. I need 2 zones and my original plan was simply to have 2 zone valves , controlled by my 2 Google Nest Thermostats as On/Off thermostats. However I came across something interesting page 26 of the boiler manual (refer to...
  10. A

    Choice of BTU calculator

    I have been trying several BTU calculators but came across inconsistent results using the same criteria. Could you please let me know which BTU calculator you find the most reliable?
  11. A

    Size of hole for 60/100 flue.

    I need to make a hole for a 60/100 flue for an Intergas Rapid 32 boiler which is soon being commissioned. The flue will be going through a plasterboard, PIR insulation board and cladding. What is the contentious regarding the diameter of the hole for 60/100 flue going through the above...
  12. A

    Conductor area for induction hob cable

    That's perfect, thanks to all!
  13. A

    Conductor area for induction hob cable

    I managed to get the instruction manual from Bosh at http://media3.bsh-group.com/digitalusermanual/9001163781_G.pdf Does the manual imply that there is one single config if the unit is connected to either a standard socket or a cooker circuit (i.e. Live on pin 3 and Neutral on pin 5)?
  14. A

    Conductor area for induction hob cable

    I added a couple more photos below. This is weird, the user manual does not specify which connector is live versus neutral. There is also no such indication on the plastic flap/cover (both sides) which covers the power cable itself.
  15. A

    Conductor area for induction hob cable

    Thank you, this is much appreciated. Last question if I may, the power connectors underneath the PUE611BF1B unit are labelled 1 to 5 (with Earth), it does not clearly identify which is the live versus neutral connection. Due to the installation guide not containing much details, I have to rely...
  16. A

    Conductor area for induction hob cable

    Well spotted, could I simply connect a 6mm2 3 core cable to the live/neutral/earth underneath the unit (as shown in the photo below) and then to a dual cooker connection unit? Note that my HOXC3UB3358BI oven is already connected to the cooker circuit.
  17. A

    Conductor area for induction hob cable

    Hi, I need to replace the power cable of a Bosh Serie 4 induction hob (model PUE611BF1B). The flex cable that came with the unit has a standard UK plug (the unit can deliver up to 3.7Kw). I have some spare 2.5mm2 cable with solid core I could use which I know will be fine, however I would...
  18. A

    K08 Spanish slates

    Does have anyone have experience of using K08 Spanish slates? Are those comparable to Cupa H3? Ref: http://www.k08.es/ Thanks!