    Min distance between vertical flue and gutter

    The manual of the boiler I would like to buy (i.e. Intergas Rapid Plus 25) shows the following: However my specific set-up is not really showing, do you think I can get away with 25mm distance between the gutter and the vertical flue? Or does it have to be 300mm? Thanks!
  2. A

    Min distance between vertical flue and gutter

    Hi all, As per diagram below (sorry it was quickly drawn), I would like to install a boiler in a lean-to. The gutters are shown in red, how far does the flue (shown as a thick arrow pointing up) need to be from the gutter (the top gutter in red)?
  3. A

    Balancing issue since moving from vented to unvented.

    That's correct, the pump moves the water towards the boiler.
  4. A

    Balancing issue since moving from vented to unvented.

    I cannot see it, it is missing. I can see that kit 230336BAX should come with all the following: I found a shop with the part in stock but they only sell the actual thermostat (other parts such as pipe, metal plate are missing): Can a plumber still install it?
  5. A

    Balancing issue since moving from vented to unvented.

    He wrote to me "all safety measures in place", I am still awaiting for him to confirm he either installed an overheat thermostat or if there was already one in place. There was one day I was out when he was doing some work, so he might have installed it, though it does not sound promising as he...
  6. A

    Balancing issue since moving from vented to unvented.

    @ianmcd & @Gasguru , I hope you can help me a bit more resolving the issue with my "blocked" cold feed, actually I am now sure it is blocked, here is the story so far. Basically I have 2 Speedfit manifolds (refer to the photo below) serving a total of 7 radiators: The first manifold...
  7. A

    Balancing issue since moving from vented to unvented.

    @Gasguru I am very impressed, not many people know about this Spartan kit! A lot of the plumbers I got over the years ran away when seeing it. Interesting piece of kit (I attached a brochure if people are interested), but after so many years of loyal service it is now gone. Believe it or not I...
  8. A

    Balancing issue since moving from vented to unvented.

    I do now have an expansion vessel (though it is grey) and a gauge which the plumber advise to get to 1 bar. Previously the open vented system was fed through a pump (refer to the diagram below): Still using the same pump, the only difference is that the old cylinder and expansion vessel...
  9. A

    Balancing issue since moving from vented to unvented.

    It is a Baxi backboiler 552, old but reliable, it is being serviced every year, last serviced in September.
  10. A

    Balancing issue since moving from vented to unvented.

    Thanks Ian, all the issues I described above were with heating only, i.e. with HW demand off. I could get all the radiators to heat up but very challenging, currently I had to shut off 2 radiators completely (TRV + lockshield) from the hallway to ensure the bedroom ones are working. PS: I am...
  11. A

    Balancing issue since moving from vented to unvented.

    I recently had a vented indirect cylinder (fed by a tank in the loft) replaced by a unvented indirect one (fed by the mains). The plumber left me with a leaking pipe causing the pressure to drop, not a great start. As he never came back to fix the issue, I had to drain the system to replace the...
  12. A

    Max distance to boundary for vertical flue

    I need to determine the best location to install a combi boiler. Am I right saying that a vertical flue must be at least 30cm away from the boundary? I could not find the details from http://www.a1gassafe.co.uk/pdf/TECHNICAL_BULLETIN_231.pdf but...
  13. A

    Wire exiting wall into kitchen cabinet.

    Thanks sparkwright, I think the answer to the next question is No but would like to check; is this allowed for an electrical cable to exit a wall without using a flex outlet place, and to go straight into the cabinet unit where a socket would be attached to that cable?
  14. A

    Wire exiting wall into kitchen cabinet.

    Thanks winston, I am pretty sure to get a METOD Ikea kitchen, the instruction manual for the over unit does not give specific dimension (available from https://www.ikea.com/gb/en/assembly_instructions/metod-base-cabinet-for-built-in-oven-sink-white__AA-2235736-3_pub.pdf) and it looks like the...
  15. A

    Wire exiting wall into kitchen cabinet.

    I need to get my electrics prepared before a new kitchen is being installed. Regarding the integrated appliances, I was going to get some sockets installed on the wall just behind the oven and dishwasher. However I read it is more convenient to install the sockets inside one of the adjacent...
  16. A

    New breathable membrane

    Thanks datarebal, an thoughts on Proctor Roofshield? It also seems highly rated.
  17. A

    New breathable membrane

    Thanks guys, is the Klober Permo Forte definitely a breathable membrane? I am asking because I will only at 25mm gap between the insulation and the slates, hence I am required to use a breathable membrane.
  18. A

    New breathable membrane

    I need to choose a new breathable membrane for my roof which is getting re-slated, any advice on efficient membranes? Permavent Max Membrane is on my list, what do you use?