  1. D

    My Photo of the Week

    I remember my Gran plugging her iron into the light fitting using one of those adaptors
  2. D

    Ring Final Zs question

    I think the plug top test lead could be at fault, possibly open cct on Neutral. The meggar uses the 3 lead test for non trip efli measurement and I know if the neutral croc clip comes disconnected during the test the display reads trip. The non trip test applies 20A L-N and 15mA to earth.
  3. D

    Strange socket in kitchen

    Why not ask him to do it.
  4. D

    Plastic Back Plates for Ceiling Roses ?

    Pity they don't plaster ducks to put on the wall :D
  5. D

    consumer unit tripping

    How are you measuring the 'short circuit'? With a multimeter? set on continuity? WHAT!!! That would make the cct live!!! Perfectly normal to read a very low resistance as N-E connection somewhere depending on earthing arrangement for the supply You have now isolated the nuetral...
  6. D

    What tools would you not be without ?

    A good quality LED head torch with rechargeable batteries
  7. D

    question for the genius people on here

    No 1 Joule is 1 Watt second
  8. D

    question for the genius people on here

    Joule is a unit of energy Watt is a unit of Power The two are related by Power = Energy per unit time (second) C.F the amount of electrical energy you consume is measured in Kilo Watt Hours. So for the 360 J defibrillator the voltage/current and hence power will be time dependent...
  9. D

    Amps per phase for 3 phase?

    Thanks Harrry That was a good bit of revision for me it's xx yrs since I did my Electrical Eng degree.
  10. D

    Consumer unit, is the following acceptable practice ?

    was that on the ramp test? You really need to determine the cause of the tripping especially if ramp test is showing 30mA trip current. I don't think changing the DB will eliminate 'nuisance tripping' if present RCD is within spec. All it will do is limit the 'nuisance' to fewer ccts...
  11. D

    Insulation resistance test on shower!!

    From your original post in red I can only assume you mean do you leave the cct connected - answer no - you would disconnect conductors from RCCB to carry out IR test
  12. D

    Going self employed - any advice

    Get a load of business cards printed and always carry them with you. You never know when or where you're going to meet someone you know and each person you meet is a prospective customer. Give a wad of cards to all your family and friends so they can pass them on to their friends and...
  13. D

    Bodge Job - Why?

    Nature of the job!! Electrics are out of sight out of mind. "All that work just for a couple sockets the other side of the room"
  14. D

    Hallelujah! Fing Rinal Finally Sees The Light!

    Point taken but can't you two go outside and sort your differences in the old fashioned way!! It's all going a bit OTT at present
  15. D

    Hallelujah! Fing Rinal Finally Sees The Light!

    FFS let this rest otherwise this site will degenerate into to the sort of slagging matches that appear on a site that sounds like helix and mending. The purpose of this site is to help DIYers - sometimes being harsh to save them from themselves, other times we can point the more knowledgeable...
  16. D

    Isolating Bathroom Electric Shower Supply.

    The important aspect is to isolate the old shower circuit from the consumer unit so the wiring cannot be re - energised. i.e. disconnect within CU and remove cabling from it. Have you ever worked on a CU before? DO you feel confident in removing the cover from the CU? Even with the...
  17. D

    ring circuit

    Not in Scotland
  18. D

    outside lights

    Same with me but just trying to save OP the hastle and expense of notifying. TBH I don't know what LABC would do in this situation unless they were just out to make money.
  19. D

    outside lights

    Good point, so the short length of cable coming from a connection inside the building entering the back of a PIR flood is ....... ? I can see the difference if there was a run of fixed wiring on the outside of the building.
  20. D

    30 spotlights 1 dimmer switch

    Apart from the obvious fire risk of installing this design of light fitting in a flammable material have you considered the effect on the structural integrity of the stairs of drilling 30 - 85mm holes.