  1. N

    primatic cylinder

    ok thanks.
  2. N

    primatic cylinder

    would you recommend in the loft or in the cylinder cupboard also automatic or manual
  3. N

    primatic cylinder

    draining primatic system again this week, would it be a good idea to put in a air vent valve on the hot water pipes, to help with any air locks we might (probably will get when the system is filled back up), as the last couple of times, we've had to reverse fill it to get water at hot taps. any...
  4. N

    primatic cylinder

    feed back on primatic cylinder, system has a pump on under floorboards, i take it this is for the central heating, anyway having drained system re-run pipework and fitted new rads, proceeded in filling system back up. Opened hot taps, cracked open stop cock, left to fill for eternity, no water...
  5. N

    primatic cylinder

    yes it is from 70,s i shall be draining system on wednesday will let you konw the results, if you think of anything else i need to know about please post up, once again thanks for help
  6. N

    primatic cylinder

    do you also have to blank off the entry holes into the tank aswell as the pipes or is there some kind of special adaptor required. forgive me if im wrong but i thought you could not bung primatic systems also the pipework seems to be 22mm not 28mm as standard on gravity hot water will it still...
  7. N

    primatic cylinder

    were is the best position to plug flow and return
  8. N

    primatic cylinder

    yes there is an immersion switch next to cylinder.
  9. N

    primatic cylinder

    wanting to drain heating system on primatic cylinder, but want to leave empty drained for 2 days will this effect the domestic water system or can i still use the domestic system. If so what is best way of achieving this any help ismuch appreciated thanks.
  10. N

    vauxhall astra 1.4 year 94 L reg overheat fault

    my astra thermometer, has recently gone straight onto the red whilst driving, it normally does not move off the blue whilst driving, unless you get stuck in traffic jam. Whilst driving home from lakes thermometer stayed on red even with the heater full on in car, then i heard a hiss, had a look...
  11. N

    ideal isar he30 condensing combi boiler

    checked all wiring, all ok, i take it this meant that the pcb has had its day so i double checked with technical help at ideal, they also confirmed this. So instead of having problem after problem with these inefficient boilers, can anyone recommend which boiler to...
  12. N

    ideal isar he30 condensing combi boiler

    update on boiler, having put new air vent in, and putting boiler back together, when you switch boiler on it blows the T3.15 fuse in the boiler, any suggestions what might be causing this would be a great help. Thanks.
  13. N

    ideal isar he30 condensing combi boiler

    brown water is from right side of heat exchanger, definately looks like its come from air vent, taken vent out i shall fit new one before deciding on new boiler.
  14. N

    ideal isar he30 condensing combi boiler

    has anybody ever come across automatic air vent leaking water, on the ideal isar he30. at first i thought heat exchanger had give up the ghost but ive just stripped boiler and it looks like the water which is brown has come out of the air vent and leaked all over the boiler. any suggestions...
  15. N

    baxi solo boiler

    [checked system tanks, water levels ok,decided to replace head on pump as i turned isolation valves off to empty pump, 1 stated dripping as they always do,should have known better but it saves draining system down. whilst draining water off pump from screw on front of...
  16. N

    baxi solo boiler

    feed back on system starting to think it could be pump, everything seems to be working correctly, just that boiler goes off after short while whilst calling for hot water, pump seems to be quite noisy as though its grinding might not be pumping water away quick enough also pump gets red hot to...
  17. N

    baxi solo boiler

    went round to check system, system is s plan all elec,s ok mv are working it gives a small amount of hot water, boiler does,nt stay on long enough to heat sufficient hot water,works fine on heating would i be right in saying its either cyl stat or overheat stat on hot water pipe...
  18. N

    baxi solo boiler

    have,nt been around to check yet thought i would ask question first , incase it was something simple
  19. N

    baxi solo boiler

    my baxi solo boiler will not work when trying to get hot water, only works on heating any ideas will be great help.
  20. N

    bleeding of radiators

    thanks i shall pass message on probably do job myself, did,nt know it was hydrogen