Search results

  1. B

    pump runs continously at night

    If its a zone valve micro switch then the boiler will be firing as well heating dhw or htg. There maybe a faulty over run switch in the boiler.
  2. B

    Charge

    Hey Softus ya musta heard the wagon wit band on. Oilman I'll wont this movin to general disscusion now.
  3. B

    No Hot Water after draining down system

    It wouldnt of blown up but would of turned itself into a kettle boiling the water in the cylinder & left alone would probably damaged the coil seals boiled up in to the header tank which if plastic would loose shape until it collapsed. seen it done once. BIG MESS.
  4. B

    Baxi Solo 2 Overheating Problems?

    1 should be enough on a good sized rad. U have a build up uf scale inside the heatexchanger if the system was run without inhibiter while u had the air problems. Also depending on when ya boiler wasmade the early models had the over heat sensor fixed between the flow & return ports on the...
  5. B

    Charge

    Hey if ya go'in get us a tin of elbow grease 2x long stands & a bucket full of insperation & i'll pay when u fitt my Tueco steamcabinet 4 £30.
  6. B

    Shower LUKE Warm Help Please

    The wax capsule is in the centre of the thermosta side of the shower it has to be completely stripped down to get at. Would it be easier to fit a new valve or even better get an installer to fit a better quality valve to fit & forget . Aqualisa or mirs valve will give years of good service.
  7. B

    CH only when HW on

    That is an old timeswitch but it might be ya system that has to work that way .it depends if its gravity hot water or fully pumped. as for not witching off if must be knackered so replace it asap. maybe a Drayton tempus 7 or an ACL LP 722 depends what control u want .24hrs or 7 days different.
  8. B

    Additional Radiators

    It a case of pennys to heaven rather than from. the biggest draw back with rads is even if you can heat it u dont want to be heating it it all the time the heatings on. consider fitting a zone valve with a stat or timer or programable stat to avoid heating times u may not use the room.
  9. B

    Soil/Waste pipe question

    Ug pipe in its nature is for under ground. it is not suitable for sunlight just as is blue mdpe pipe isnt. above ground inside it may be ok but id check with building control 1st as i wont risk it . UG is UG so is it worth the risk.
  10. B

    CH system leaking under floor

    I would say u must have a leak under the floor as a leak at that rate would overflow the lower tank . & if it aint the heating . if the lower tank is the heating then that would be the 1 over flowing & not dropping. Can u not bung the system & fit a couple of gate valves where the main circs for...
  11. B

    c/h pipes and concrete floor

    If running in copper the cocrete will corode them. depending on length of run id use copper plastic coated 10mm & insulate with thin wall lagging for expansion as well. if using plastic pipe the just the lagging for expansion.They do run under floor in plastic with out insulation but u must...
  12. B

    neptune exotic shower problem

    Without knowing its origin its a needle in a haystack. sounds like a special from a shed perhaps. might have to replace with a wel known brand Mira sport 9.5kw. At least u can repair quality products. Hey just watch sombody will probably know it within 10 mins of this post.
  13. B

    neptune exotic shower problem

    sorry never heard of it but sounds like another dodgy shower with a dodgy pcb or switch.
  14. B

    Training

    Just read ma post back & had no intension to sound flash Out of the £1800. the left hand man takes 500 & £1300 - expeni's may leave a grand to play with but after 26yrs at it i dont know anything else other than its probably the best it gona get the way the paper work & regs r go'in.
  15. B

    Shower woes

    Those pressure's seem to low to me .If the unit was workin ok b4 then i wonder if ya mains supply pressure has dropped. will the flat above let u test there pressure or even a couple a houses away. Ring the local utility company to find what the static pressure in your area is . you may have a...
  16. B

    Low flow from power shower ?

    I'm sorry to say that the istallation may have a design fault compiled with low quality products ending in poor performance ,but thats only an opinion with out visual backing. The supply piework to the pump & from the pump to the valve must always prevent air from collecting.
  17. B

    NOISY SHOWER PUMP

    Its the newer model of the worst on the market i'd say. £100 B&Q special. Its probably 1 to 1.5 bar best option is to have it changed to a STUART TURNER 2 bar MONSOON . £250 + fitting approx but the dogs & as quiet as u'll get.
  18. B

    Training

    Hang in there mate its not that much to ask if u r as keen as u sound. I think Breezer view on £11 an /hr is cool .as most are chargin £25 + +vat so the extra £7 for a pair a hands on two man jobs aint daft. Are BG not takin on any more. 3 yrs ago they were going mad 4 good lads keen to learn...
  19. B

    Luke warm shower but boiling hot water!

    You keep refering to the shower head as at fault the head should be ok but it will be the valve. over the years i'v found lots of cheaper end of the scale thermostatic shower valves use wax capsules & the life span seems to be shortend when on combis more than anything else. maybe as the combis...
  20. B

    Soil Pipe Branch issue - Ensuite, to Saniflo or Branch off?

    I wish u were nearer i'd come an do it. Any timeserved plumber with good experience should sort that 3 hrs tops £150 should kill it .u should ask around 4 a good reference.