  1. S

    Swapped door and window in current openings

    Means of escape is now better than before as it was previously compromised by the original kitchen layout. Think the "complaint" was by the inspector who has been next door for building works and thought he would generate some income for the council. For me I thought the spirit of the directive...
  2. S

    Swapped door and window in current openings

    Cheers guys, probably the inspector used to be a traffic warden
  3. S

    Swapped door and window in current openings

    Ok thanks seems like very much sit it out, worst case will need to change the glazing in the door. Think this has all come about by neighbour having work done and inspector seeing the "building work" that I have done. Understand if lintels were involved but they were all in place. The U rating...
  4. S

    Swapped door and window in current openings

    Hi, Around 2 years ago I moved a back door (PVC probably around 15 years old), to where a window was, the window I took out was much larger than the door so is under an exsiting lintel and used themlite blocks to fill opening (9 inch brick work). Where the door came from had a small side...
  5. S

    Fit Hive 2 to my Vaillant ecoTEC plus 837 - please help!

    I would have gone for the Vaillant VRC470 or 470f' assuming radiators are sized correctly. OK not contollable via a web app but you could then benefit from weather compensation. Obviously if you can achieve savings by controlling via phone due to your lifestyle then you may have made the right...
  6. S

    Vaillant ecotec plus 418. Many problems.

    Just get them back they have messed up the wiring. However putting that boiler on a potentially dirty system may be the cause of other issues. S30 is fine means no call for heat from either the roomstat or cylinder stat.
  7. S

    Pottertom Prima 80F Pump Overrun Issue?

    Do what I done. Install a timed relay on the pump. Never had a overheat trip since.
  8. S

    Vaillant ecotec plus 418. Many problems.

    s.8 is anti cycle mode. The boiler has reached and exceeded the target flow temp. Quite likely after the first long burn when it has modulated down but not reached the target on the cylinder stat. Boiler will then fire at 80% approx of its rated max 18kw regardless of d.0 due to heat in pipes...
  9. S

    Vaillant ecotec plus 418. Many problems.

    so you have had work done that has not fixed the issue? Did you pay for this work. Sounds like wiring issue but
  10. S

    Vaillant ecotec plus 418. Many problems.

    so what happens if you turn down stat on cylinder? What are the scodes whilst the boiler is running the pump? Flow temp this time of year should be set to around 70.
  11. S

    Vaillant ecotec plus 418. Many problems.

    Is you pump on 3? What S codes are displayed when playing up? Are the valves on the pump fully opened? By afterun time I guess you are talking about pump overrun 20 is the default for the anticycle timer. Setting the water temp tap sign has no bearing on your install. Set D.0 to 8 do you get a...
  12. S

    Father in Law, Back boiler with gas fire put AR

    right the boiler/fire front is listed as a Glow Worm Royale 24-6 have asked FL to check and he is saying there is a picture of a hearth but no dimensions. After speaking further it is a photo but no dimensions. Tried explaining that back in the day big fire places were all the rage and if no...
  13. S

    Setting auto bypass

    Ha ha look what google found assume this is correct info? http://www.diynot.com/diy/threads/du145-bypass-valve-how-to-reset-the-dial.267969/
  14. S

    Vaillant ecotec plus 418. Many problems.

    ok so forget what I just said as not the advanced controls. Sounds very much like a simple wiring fault or the programmers acting up. What flow temp you set to Also model of roomstat
  15. S

    Setting auto bypass

    Hi, The boiler vaillant 428 I believe requires 1200L hr, pump is grundfos 15/60 on setting 3. Auto bypass is I believe a honeywell DU145 cannot find marking but has settings from 1-6. Have just switched on boiler and could feel both sides of the bypass warming up. Bypass was set to .1 but...
  16. S

    Vaillant ecotec plus 418. Many problems.

    What controls do you have? Maybe the anti legionaires kicked in?
  17. S

    Father in Law, Back boiler with gas fire put AR

    service booked for Tuesday. My partner has been round there and also it says it requires a hearth to be installed. It is a wall hung fire front with fake coals with a glass front that is intact. Floorcovering is carpet. Is this correct?
  18. S

    Father in Law, Back boiler with gas fire put AR

    And the answer is? Yes they have gone from NCS to AR, but just wanted constructive advice. Might be time to get the 5inch core cutter out if the ducting issue is correct?
  19. S

    Father in Law, Back boiler with gas fire put AR

    Hi, Father in Law is having a new gas pipe installed into house by supplier/transco. This morning prior to the visit for the works tomorrow a fitter has put his BB at risk due to inadequete ventallation. House in a 1930 terraced house no cavity walled with separate kitchen with Gas hob and...
  20. S

    Question regarding controls for vaillant 624 and unistor

    yes of course this will not be a problem. Howerever you will loose out on some of the advanced features of the boiler knowing what temp the cylinder is at which could cost you a bit more gas in the long term