    Drops from bottom of radiators

    +1 Gas PTFE - 7 turns - turned on opposite to the tapping thread so it doesn't unravel when tightening.
  2. Madrab

    Reseal a Walk-in Shower Cabinet

    Your enclosure can be taken off and all the bad silicone cleaned off and then put back together and re-sealed. As suggested, a shower should be dried after use and cleaned regularly. That and a good quality anti mould silicone needs to be used.
  3. Madrab

    Plastic 1/2 cover to go onto rad brackets

    The plastic shims are to stop the rad from rattling/clicking on the bracket. I would normally expect to find them. Yes the rad can be fitted without them, could it click without them, possibly.
  4. Madrab

    How to unscrew this kind of tap?

    get longer arms ;)
  5. Madrab

    Who Needs DIY Bodges

    Wouldn't be the first time I've hole sawed through an I-Beam for pipework, good quality bi-metal hole saw with a good drill and lubrication will make short work of it. Just make sure the holes/pipe is protected against rubbing damage.
  6. Madrab

    Who Needs DIY Bodges

    Who's to say it was a professional? Looking at the soldering he wasn't a very good plumber never mind a professional IMO. A lot of so called professionals just aren't and a lot aren't even qualified. That's the trouble with plumbing, no regulation and the industry has made it so easy, where...
  7. Madrab

    Which dow 785 ?

    I have yet to find any silicone that does not eventually go black, even the mould resistant ones, neutral or acetoxy. The trick is drying, don't let silicone stay wet, it can be as simple as that.
  8. Madrab

    Heating but no DHW

    Programmer sends 240V to the cyl stat > cyl stat sends that 240V out to the 2 port > that 240V powers the 2 port valves motor that opens the valve > the microswitch in the 2port valve is triggered by the valve opening and sends 240v, that is running in on the grey wire, over to the orange wire...
  9. Madrab

    Which dow 785 ?

    Just ensure it's mould resistant sanitary silicone. I have used both and haven't noticed any difference but as suggested the neutral cure is more designed for plastics/acrylic. Good silicone is a practice thing TBH. You can help it by using masking tape and silicone finishing tools and the...
  10. Madrab

    What is the purpose of this pipe?

    You would always want any AAV to be above the highest spillover level of the highest fixture it is connect to. Why I didn't suggest an Antivac bath trap. If the AAV is placed anywhere other than close to the bath trap, then shallow bath trap seal could still be pulled if the bath empties...
  11. Madrab

    Unvented cylinder - cannot turn off immersion

    Looking at that pic the immersion isn't connected to anything. If it was there would be a live and neutral connected to the 2 top terminals on the left hand block.
  12. Madrab

    Boiler Gurgling/Banging (shower use only)

    Restricted plate heat exchanger most probably, could be cleaned and flushed. Goodness, haven't seen a Sabre in many years - Rebadged old Vokera Compact
  13. Madrab

    Immersion hot water not lasting long enough!

    An inline shower booster is small beer, nothing like a proper shower pump and it's really easily removed when leaving without any obvious signs apart from a small section of replacement pipe.
  14. Madrab

    Heating but no DHW

    Be careful, if the HW 2 port is manually latched, there will be no HW temp control. The cylinder stat controls power from the programmer to energise the valve and then shut's it down when the it reaches set point. If the valve is manually open and the boiler is being controlled by the room...
  15. Madrab

    Radiator design contains no water

    The ribs in the rad have to be what will carry the water through internal waterways by the looks of it, no other way it could work. TBH though , cant say I've ever seen that actual type before.
  16. Madrab

    Mira Mode shower and bath filler tank size

    When you can get a suitably sized 25gal coffin Cold water cistern for not much more than £100 then what the feck are they charging £900+ for?? All they would be doing is > isolate current > drain > disconnect > build up new > reconnect >check and test. Not a lot of time or effort in that. If...
  17. Madrab

    Blanking Off a Tap Tail

    You could get an M10/M12 blanking plug, tap tail size dependent, with a suitably sized O-Ring and use that
  18. Madrab

    What is the purpose of this pipe?

    OK - certainly seems to be a secondary vent, to vent the basin/bath waste run and protect the traps. Cut the vent as it leaves the vertical stack and seal it up, then fit a McAlpine anti vac trap on the basin. Fill the bath right up and let it go and make sure it doesn't self syphon the bath...
  19. Madrab

    Rads - your rules of thumb

    'Oversizing' the system rads can allow the system to be run cooler, whilst still satisfying the rooms heat loss requirements, that obviously reduces energy costs with lower deltas and more consistent condensing and reduces the strain on the boiler. Its how low temp heat pump systems are...
  20. Madrab

    Immersion hot water not lasting long enough!

    An electric shower will not only require the install of the shower with it own dedicated cold water supply, it will also require it's own dedicated electrical supply, what cable size/MCB rating will be determined by how powerful the shower being installed is. That and if there is space in the CU...