  1. C

    Worcester Bosch 240

    The trombone pipe costs about the same price as a pack of worcester bosch o rings,I allways fit a new one of these whenever i replace the diaphram on these divertors.
  2. C

    Rielo RDB burner strange problem

    Tested the motor and it was giving 50v through the white wire!Fitted the replacement and low and behold worked a treat! Pressure was just below 10 bar,cust had found out the manual,presure should of been 9.8 bar,so left as it was,just one of them hard to explain breakdowns i guess
  3. C

    Rielo RDB burner strange problem

    Had no manuals to check it was correct but pump was giving a steady 150psi,Its an auto ranging digital multimeter that i use,and showed a steady 220v on control box input connections.
  4. C

    Rielo RDB burner strange problem

    Not struggling for fuel as it is only 6ft from tank and all filetrs are clean and the oil comes out the pipe boiler end at a good flow rate. I determined the voltage going to the coil by disconnecting the wires coil end and connecting them to a multimeter,and believe it or........looked at the...
  5. C

    Rielo RDB burner strange problem

    When i return with the motor in hand ill try them 2 things,motor had 3 wires black blue and white i think so will check the white wire voltage,dont work on many of these burners and just my luck there was nobody in at riello to answer phones today,thanks for the info,sounds like it could be the...
  6. C

    Rielo RDB burner strange problem

    Boiler fires up and sounds like its strugling for fuel,cleaned out filters,checked oil pump and all ok.The voltage going to solenoid coil varys wildly between 0v and 210v which probably causing the solenoid to keep restricting the flow of oil causing the problem. I have tried a new control...
  7. C

    manufactures jobs

    Most manufacturers are now looking for people with a few years proven experience on service/breakdowns,worcester bosch like you to have 4 years and vaillant 3 years from the jobs ive seen advertised on various websites,besides rig careerline.co.uk advertise a few aswell.
  8. C

    Faulty motorised valve?

    Just replace the head on the valve,if you feel confident with some diy electrical work,if not its an easy fix for a boiler engineer.
  9. C

    Central Heating Problem Pump & 3 Way Valve Not Working??

    Power goes from timer/clock to thermostat,then onto 3 port valve which will then open and send power to the boiler and pump,b4 changing the pump make sure there is 240 volt going to it.usually on the thermostat if its been wired in correctly linking the red and yellow wires will by pass it and...
  10. C

    Vokera Linea 24 'ERROR CODE 01'

    last time i had this fault it was the ignition pcb on the gas valve edit-just noticed the date of the op!
  11. C

    Riello Burner

    It may not be a problem on the oil pump,could be faulty solenoid or photocell.
  12. C

    grant Oil Boiler

    "engineer has dissapeared" You sure hes not inside knocking to be let out?lol
  13. C

    Neff Gas Hob - Flickering Yellow Flame and odd Odour

    Probbaly a bit of crap under one of the burners,just play it safe and wait for corgi bloke to come and sort it
  14. C

    Oil Boiler Noise..

    if you move the boiler,it would be classed as a new instalation and a condensing boiler would need to be fitted to comply with building regs,youll probably find that you can just hear the burner more now that the wall has been removed.
  15. C

    Grant 90 combi (oil) luke warm dhw

    Got to go and look at one of theses boilers as customers says the dhw is only luke warm,serviced quite a few of these but it sounds like this problem has nothing top do with the burner as they say boiler is firing up,any pointers what to look for? previous engineer turned up one of the stats but...
  16. C

    Riello oil burner problem

    Try your photocell,next time fan runs but it wont ignite,disconnect it,if its at fault burner will ignite then go out after a few seconds.
  17. C

    Baxi Bermuda 45/4m - Pilot related problem

    Press in the grey button and hold it in,press the black button a few times which will cause a spark and ignite the pilot,keep the grey one pressed in for 10 seconds after it has ignited,let go and it shoul;d stay a light if thermocouple is ok.
  18. C

    constant air pockets

    Is the f+e pipe blocked?sounds like your system may be low on water
  19. C

    turbomax-strange problem........

    Will re-post topic in there once i get the email back,only registered my details today.
  20. C

    turbomax-strange problem........

    loked at a turbomax 282e on friday,first time ive worked on these boilers,problem was-fan running,no igniton,blew through aps heard it click,no ignition still,pulled pcbs out of the casing to check voltage on aps and boiler started working all of a sudden!-put the pcb`s back into casing and...