    Worcester-Bosch boiler problems

    If you have a service with a pre existing fault which remians after,then yes the service should be paid for especially if its an intermittent fault which did not show during the service,ive gone to loads of services to be told by the way it isnt wrking properly b4 i start,a service sometimes...
  2. C

    riello burner motor buzzing and then lock out

    did you fit the oil pump motor yourself? if so you will need an engineer in to set the oil pressure/air mixture adjustment otherwise it may run but not last too long!
  3. C

    riello burner motor buzzing and then lock out

    Thats the one yeah,shouldnt jam the motor though even its its worn.
  4. C

    riello burner motor buzzing and then lock out

    slacken off the grub screws on the oil pump and try it then,may not be located properly.
  5. C

    ISAR HE30 BOILER PROBS!!

    Cloudy hot water is nothing more than he oxygen in it,nothing to do with a plate heat exchanger cleaning itself.
  6. C

    orange light on boiler but not firing

    Have you tried pressing the overheat stat reset button aswell?
  7. C

    Random lockout - Potterton Statesman 65/85 oil-fired boiler

    see if the motor will start with the oil pump disconnected,or just try loosening the grub screws holding the pump to the motor,had a few of these which would not start up after a pump/motor replacement due to the pump being slightly out of line onto the motor housing.
  8. C

    thorn olympic 38/50B Boiler

    The coil in the cylinder may be leaking ,mixing water from the ch system with the hot water in the tank,if it is then=new cylnder.
  9. C

    HeatSlave 20/25 - Operation of Diverter Valve

    The replacement valves for the heat slaves come with a terminal block attatched to connect to the pcb,should take bout an hour to drain boiler and replace whole valve.You may not see the lever move but in dhw mode the lever will move with some resistance,in ch mode the lever will move freely.
  10. C

    worcester 35cdi hot water problem

    does the boiler fire up when you turn the water on only at high pressure?
  11. C

    Worecester HeatSlave 25/32 - DHW Losing Temperature

    Sounds like you have found your problem :)
  12. C

    worcester 28i rsf combi boiler

    They sound like the overheat stat and the air vent.The reset button is the oval shapped button on the front panel which will flash red when there is a fault if i am thinking of the right model.
  13. C

    Worecester HeatSlave 25/32 - DHW Losing Temperature

    Possibly divertor valve head,and or body,if its the grey plastic type head valve is spring loaded but sometimes gets stuck at bottom,easy to remove the head and take a look.
  14. C

    Clicking radiator!

    Your towel rail is probably fitted without a trv,most of these are,this will then also act as a bypss should all the other rads close off on their trv`s.
  15. C

    Oil Heating: Boiler won't start after running out of oil

    If the boiler wil not start and there are no lights on it,basically it i not getting any power sent to it,due to overheat stat tripping,boiler not getting a signal to turn on,or a fuse blown ,have you checked the fuse in fused spur to the boiler?
  16. C

    Oil Heating: Boiler won't start after running out of oil

    If it it was the burner that had locked out pressing the reset button would usually start the motor up,but seems you say everything is dead i suspect the overheat stat has tripped,or the motor has had it,does the reset button light up?to bleed the oil through,u need to loosen the nut on the side...
  17. C

    Oil Heating: Boiler won't start after running out of oil

    What is the make/model of boiler? after pressing the reset button on burner does burner try to start up/make any noise at all? are any lights on the boiler iluminated.Have u tried pressing the overheat reset?this is usually under the control panel when the main door is removed/open and is a...
  18. C

    worcester 24i junior dhw problem

    When tap turned on without ch fan starts and it locks out within 5 seconds before burner ignites,input into flow turbine is correct,just strange hw it does not cause a lockout when the heating is on .
  19. C

    worcester 24i junior dhw problem

    Looked at one of these friday,dhw will work ine when heating is on,turn a tap on without te heating and fan will sart up and boiler goes to lockout,tested the flow turbine and im getting the required 5vdc to it but only 0.5v dc instead of the 1.5v to 4v when tap is turned on,but manual says this...
  20. C

    loss of pressure in my Worcester oil heatsalve 12/14

    Try manually opening the prv a few times sometimes this will re seat it andstop it leaking,also as mentioned check the expansion vessel