  1. C

    glowworm will not spark

    Well its not gona ignite if youre not getting a spark,the ht lead may be shorting out somewhere.
  2. C

    hawk boilers? anybody worked on them??

    Not come across one of these bilers so far but goto look at 1 tommorow cust says dhw is ok when used on its own but when heating is on at same time dhw goes cooler,any body come across same problem on them>??
  3. C

    Oil boiler on constantly

    Do you have a frost stat at all?If you do this may be set too high.
  4. C

    Tightess tst on lpg (no test nipple)

    Whats the proper procedure to do a tigtnss test on a lpg instalation when there is no test nipple fitted-ive been using the inlet nipple on the gas valves,got a corgi inspection soon and wonderng if they aprovethis method.
  5. C

    Replacing old Room Thermostat

    I like to use the honywell cm901 £43 from screwfix.
  6. C

    Ferroli Modena 80 E - NO CH, but light for demand of CH on

    Does the boiler operate normaly when you turn the hot water tap on?
  7. C

    Noisy motorised valve

    It sounds like you have been given a replacement synchro motor head,isolate the electric and repleace the old one with the new one and see if it solves the problem,but usually when its the motor what has gone the bolier will not fire up,i think you may be looking at replacing the whole head of...
  8. C

    Worcester 14/19 CBi problem

    U sure that you are measuring it in dc voltage? had to replace a gas valve on one of these yeasterday-solenoid had packed up on it-sometimes it would ignite ok other times nothing.
  9. C

    Heatslave 12/14 no heat, in fact nothing at all.

    Yeah u can do it to either one or the other or both.
  10. C

    Heatslave 12/14 no heat, in fact nothing at all.

    Where the timer plugs into the terminal block u can unplug it and link out the ch/dhw with the 240v-this will then tell you if its a problem with timer or if it is somewhere else.
  11. C

    Heatslave 12/14 no heat, in fact nothing at all.

    The cover on the pcb really needs to come off and the live from the clock needs tracing with a multimeter to find out where it is failing-u certain its not locked out and the lockout bulb has blown,therefor not showing the fault,u say you have looked for the lockout buttons-have u actually...
  12. C

    Worcester 28i boiler switches off when using shower

    If youve got the temp of the dhw turned rite up to the max and the shower isnt drawing off a great deal of hw it might be tripping out on the overheat stat -or the over heat stat could just be faulty.
  13. C

    central heating

    do you have a room stat?
  14. C

    ideal isar -lights with a bang!

    i had got the model wrong model is actually w60p-although the boiler was badged up as an isar ive actually now found that it is and ideal imax boiler!
  15. C

    ideal isar -lights with a bang!

    il get exact model number and a pic when i go back next week-cant find anything like it on the net anywhere but was deffinately badged up as an isar.Bottom 1/4 of from panel hinged down off a magnet catch-panel behind this was a navy blue clour with a burner on/off switch to the right,and red...
  16. C

    ideal isar -lights with a bang!

    On this model of isar-a pretty new one,about 2 years old-(condensing/lpg/system boiler)there is a window on the combustion chamber whch u can see electrodes through,oblong shaped burner is bolted to top of this with fan on the left/gas valve on the right and about twice the size of an average...
  17. C

    ideal isar -lights with a bang!

    Anybody come across one of these boiler making a bit of bang as it ignites?Can see the spark coming off the electrode b4 it ignites and it looks like a very spark tbh so have oredered a new one,not sure if it is the electrode though or the board not giving it enough power-no manual there plus no...
  18. C

    Worcester Bosch 240 CH Problem

    If the pump is getting 240v to it when it stops wrking then faulty pump-if its the board that stops sending the 240v to the pump then the pcb has had it at a guess-its a bit hard to say without doing some tests on it
  19. C

    fitting a wood burner fire

    Been asked to look at fitting a wood burner fire ,anybody know what the flu requirements are for these things?Im thinking of using a length of vitreous enamel flu the out through the wall at 45 degress then up the outside of wall,but not sure of what height it would have to be,but not looking at...
  20. C

    flu regs form a wood burner

    Just been asked to fit an old wood burner type fire-only used to fitting gas oil stuff-are there any sepecial regs as regards the flu?Im guessing class one vitreous enamel flu will do but not sure of the minimum heights etc.