  1. M

    Boilers and CORGI registered engineers

    There is another thhread on this subject and I posted the following text, which has been lifted from the CORGI website, it may help in this thread too:Q: I am a qualified plumber, and have been in the plumbing industry for years. I am, however, not registered with CORGI. Can I install a boiler...
  2. M

    cost for commissioning a combi boiler

    Not true. You mustn't install any part of a heating system that may affect the gas safety of the system. At a minimum that includes putting the boiler on the wall and installing the flue. The following is lifted from th eCORGI web site: Q: I am a qualified plumber, and have been in the...
  3. M

    smelly hot water!

    Sounds like the most likely cause to me.
  4. M

    Central Heating Query

    The only possible problem with turning your stop cock off and leaving the heating on is if you have an open vented heating system. The heating header tank will not refill if the level drops for any reason. Having said that: it's very unliley to cause a problem. Turning your stop cock off...
  5. M

    Can you recommend a good condensing combi?

    The 828e is a good boiler but quite pricey compared to Worcester Bosch. WB have excellent after sales service. £1450 doesn't sound excessive for the Vaillant installed.
  6. M

    Excessive rad bleeding

    Go back to your expansion pipe and put your hand over the end to see if it's sucking air. If so you may find that your pump is set too high and turning it down will solve the problem. Although corrosion can cause the production of gas in the system it is unlikely to produce the amounts that...
  7. M

    noisy cold water mains - advice please

    Turn the main stop cock off in the street and see if it stops.
  8. M

    landlord certificates

    Plumber Will, what makes you say that a landlord can't do his own inspections? It's something I have been wondering. I asked my CORGI inspector and he said it shouldn't be a problem; although he could see that it could be a conflict of interests. If you know of something in writing let me...
  9. M

    Automotive Antifreeze/Coolant for Boiler Heating System??

    I'm listening Jeopar! You said you aren't looking to save money, you're looking for a superior product. I'd appreciate hearing the results of your enquiries. mave
  10. M

    Boiler Service

    let by test/working pressure test flue gas analysis gas rate/burner pressure clean operation of safety devices visual inspection of boiler, ventilation, flue etc.
  11. M

    furthest radiator cold

    balance the system. To start with try turning the rad valves on the radiators nearest to the pump right down. Mave
  12. M

    Locating boiler outside

    When choosing a site the following need to be considered: suitability of the site route of any flue system acceptable terminal position available ventilation , if required location of of appliance to other parts of system(cylinders, cistern) pipework route for water supplies pipework...
  13. M

    gas hob

    £40 is fine if all that he has to do is tee into the existing pipe. What if the existing is 15mm and it's not sufficient for the cooker and hob. It may be that the existing pipe needs refitting in 22mm. Or is the fitter going to just fit it and not worry about the poor pressure on the hob...
  14. M

    Gas pipe size

    FWIW, You will need 28mm from the meter to the tee, 22mm from the tee to the boiler and probably (depending on size of cooker and hob) 22mm from tee to cooker and hob tee, posssiby reducing to 15mm from there to appliances. Mave
  15. M

    Do I need a bypass or modulating pump?

    It works fine from cold and only has a problem when warmed up. With so many rads with TRVs the pressure and flow is changing dramatically when warmed up. It may be that a more powerfull pump, or one of these: http://www.plumbworld.co.uk/acb/showdetl.cfm?&DID=10&Product_ID=2989&CATID=46 will do...
  16. M

    removing gas fire making safe the gas pipe

    As it's under the floor you cant use a compression fitting, it will have to be soldered. Best get gas fitter to do it so that it can be done properly. Also best to remove it completely if you're not going to use it again in the future
  17. M

    Do boiler manufacturers charge for training courses?

    Would you like a hand off your horse it seems a bit high? I am a corgi registered gas engineer who's work does not normally include boiler servicing. I am thinking about changing direction and would like to expand my knowledge first. If you're too important to reply then let someone else...
  18. M

    Do boiler manufacturers charge for training courses?

    I want to go a on some manufacturers boiler courses. How much are they likely to cost me, if anything? Mave
  19. M

    Push fit plastic plumbing sizes and attachments etc.

    Yes you can use pushfit fittings straight onto copper. 1/2 inch can be treated the same as 15mm. 3/4 inche can be used in 22mm compression fitting if you use a 3/4 inch olive or use a 3/4-22mm end feed adaptor(or yorkshire). you may find lead in which case you need a lead lock which is a...
  20. M

    Ferroli Optima 901 Combi over pressure & PRV dump daily

    It sounds a bit like the problem I posted about recently. Could it be the expansion vessel is shagged?