Search results

  1. G

    What make of LED PIR are these

    Thats them Thanks very much for taking the time to look
  2. G

    What make of LED PIR are these

    Have these fitted to our present house Want the same at new house They have been perfect but i dont remember the name Any one recognise the make
  3. G

    Change of Use

    Had this from the builder who completed the work Floor was raised in garage 18 inches. Concrete based and damp liner then concrete again. Stud wall was double breeze block with insulation in cavity. All internal walls were double plastered. New double glazed window installed. Radiator was...
  4. G

    Change of Use

    Found a House we want to buy The owner has changed the Internal Garage into a Bedroom but has left the garage doors in place so from the front of the house it still looks a garage Inside these doors is a 4ft storage area which houses Gas and Electric meters He has not applied for planning...
  5. G

    Venting bathroom extractor to cooker vent

    Need to install a Vent into a Bathroom in a flat venting to the outside through wall would be difficult as on 2nd floor Could i install the vent up into the loft and then use a Y connector into the existing pipe that comes from the cooker Extractor this already vents outside Any advice...
  6. G

    Getting Gas meter moved vertically down 2ft in Garage

    Thanks Will try ring round some Registered Gas guys locally
  7. G

    Getting Gas meter moved vertically down 2ft in Garage

    Yes that would work So leaving the flexible pipe in place and moving the meter down
  8. G

    Getting Gas meter moved vertically down 2ft in Garage

    Its just 12" lower still leaves the Meter at just above eye level so no issue with Cars and it getting knocked hoping this can be done by RGI
  9. G

    Getting Gas meter moved vertically down 2ft in Garage

    Afraid not it has to be lowered the Rails for the Garage door pass horizontally across the meter
  10. G

    Getting Gas meter moved vertically down 2ft in Garage

    It has to move down 12" to allow the runners for the New Garage door to be fitted The Main gas feed or the Feed to the house from the meter will remain in place
  11. Gas

    Gas

  12. G

    Getting Gas meter moved vertically down 2ft in Garage

    Gas by G1nzo posted 5 Jan 2017 at 3:15 PMWant a new Garage door installed but the gas meter is in the way of the door rails What are the costs involved in having the meter moved down 2ft Same 2 Feed pipes can be used needs lowering and re fixing to the wall Who can do this work Thanks in advance
  13. G

    Outdoor LED PIR lights issue

    2 lights and one PIR sensor
  14. G

    Outdoor LED PIR lights issue

    I have emailed the electrician as these are the items that he recommended for the job and supplied I will investigate the issue of spikes on the mains as welk
  15. G

    Outdoor LED PIR lights issue

    No Nothing at all Everything else works normally
  16. G

    Outdoor LED PIR lights issue

    PIR180BK
  17. G

    Outdoor LED PIR lights issue

    They are Eterna POLY20
  18. G

    Outdoor LED PIR lights issue

    Just had 2 20w LED PIR lights fitted The Electrician took supply from ring main via a fused spur Problem is that when ever we use any appliance on the ring ie an iron that draws some current the lights come on outside Is there anything we can do Cant change any wiring as all the walls are now...
  19. G

    New UPVC Patio doors do i fill the void

    Just had New Patio Doors fitted to dining room No carpets fitted as New Laminate floor waiting to be installed BUT across the entire width of the Door there is a Channel maybe 4 inches deep and 3 inches wide full of old plaster and Debris Should i fill this void with Cement to the original...
  20. G

    Hotpoint FZFM151 freezer not freezing

    Yes its frost free model The fan at the top is not running It did this before I will empty the freezer and introduce some hot air underneath the fan And will check the drain hole Thanks for your help Will update once done
Back
Top