  1. D

    Inserting Junction into an existing soil stack

    like everyone else says just use two slip couplings, make sure you use a bit of lube or fairy liquid on the rubbers or they can move out of place when fitting the joint.
  2. D

    pressure reducing valve

    i know they shouldnt but it is the problem because if i remove it the problem is fixed im just wondering would it be a problem if i didnt put it back in.
  3. D

    pressure reducing valve

    the manual doesnt say anything about it seems odd to me that since i fitted it on the hot water the cold water pressure reducing valve on the main cold coming in has now stoppped working :S
  4. D

    pressure reducing valve

    do you need a pressure reducing valve if your hot water is pumped the pressure reducing valve is on the cold water and since the pump has been fitted it seems to block up ?
  5. D

    Header Tank Overflowing - Not the Ball Valve

    i turned the gate valve off then looked at the taps and found my problem so it worked for me but i understand what you are saying as a plumber if i did see it do that i would know it was back filling i forgot to say about the vent lol
  6. D

    NRV on a basin mixer tap?

    i would fit one stops any problems in the future with cylinders overflowing etc.
  7. D

    Experience with Slim Line shower trays & Turbo Shower Wa

    if you do feel like it might not work i always like to drop the waste pipe down as soon as it comes of out the trap as i find it can help speed the water up from slimline trays but shorter runs are better
  8. D

    Change toilet waste to washer waste.

    you can take the soil pipe from your old toilet out the vent shouldnt be a problem and most waste pipes go straight into the soil pipe anyway so that would be fine if you do find that the waste pipe smells when you fit it you could need to change the normal trap for a anti vacuum trap which will...
  9. D

    Leaking Salamander pump & hot water

    salamander pumps are easy to change the washers and as a new pump wont be cheap i would try a new washer try the parts department with salamander
  10. D

    If it Aint Broke Dont Fix It

    If it Aint Broke Dont Fix It
  11. D

    Mira 415 problem

    the other thing this could be if the pipes to the shower has been put through a stud in your wall and they didnt leave expansion room for the pipe so the pipe cant move it will make a tapping noice
  12. D

    Header Tank Overflowing - Not the Ball Valve

    this could be your coil . I have just fixed a problem like this and i found it to be ( now i found this hard to understand and im a plumber for 4 1/2 years) the main cold water to a mixer valve ie shower or bath tap etc was passing somehow and back filling the hot water. This was slowly...
  13. D

    Are these pan connectors okay?

    the swan necks are ok if your toilet has a good flush i wouldnt use a flexi ever as soils tend to " grate " off on the flexi part and can smell or become blocked
  14. D

    Slightly ruined thread on shower pipe

    i would use a hacksaw and make the thread a bit deeper also i would make sure you cant see the thread cross if you can get a knife and cut the burr off the thread this should solve the problem apart from that you need a taping set and re do the thread
  15. D

    Dimple in brand new window

    i would as them to replace and if they wont get the people who made the glass involved as a pin head mark shouldnt be there it could effect how tough the glass is and if the people who make it think this they will change it for you no problem and probs have a good go at the people fitting the...
  16. D

    to power flush or not to power flush

    it its thick sludge a powerflush wont get it out it will only remove about 70 % of it also if it is a old system it can cause valves and joints to leak from the pressures used i would stick a cleaner in the system see how cleans it comes out after that then think what to do next but i wouldnt...
  17. D

    Foul smell in lower kitchen cupboard where waste stack comes

    you dont need a vent on your stack aslong as your drains join the main drain which they do cause your stack can vent of the next doors as the drains mix the smell could be a leaking seal at the bottom of the stack theses may not leak water as it passes it quick but can smell alot .
  18. D

    Combi - Using for Hot Water with empty CH system?

    the heating system needs to have water in as this is what heats the hot what in the heat exchanger under the boiler should be some valves close the valves for the central heating and the hot water will work but only for a short time as the ch temp will rise quickly therefore turning the ch off...
  19. D

    Torbeck valve slow fill

    2 things could be wrong with this 1 debris in pipe and inlet valve. 2 pressure reducing piece has been left in the inlet valve when you fitted it try removing this but removing the valve from the toilet and refitting without it in if it had a high pressure one in you may have removed it by...