Search results

  1. R

    valliant ecomax

    Once you have filled it press the button with the flame and cross going through it. Will need a reset; my missus sometimes forgets that part, then shouts at me!
  2. R

    basin mate seal

    See here. Two posts below as of this moment.
  3. R

    feed for UFH

    I would always use 2, 2 port zone valves one to control the conventional heating and 1 for the UFH. Making you system an S-Plan. Do you have a combi or conventional H/W system. If conventional then it is 3 Zone Valves as the H/W is also a separate zone. EDIT: But maybe i miss read your...
  4. R

    New boiler, radiator expanding under pressure?

    Just to again point out. This is not an installer issue. In fact i had a lucky escape in a similar situation, working for a real tech head. Coverted from a conventional system to Combi and after 20mins of running, heard a real racket banging like a gun was going off, turns out it was a rad...
  5. R

    Need Help with removing outdoor tap!

    I guess the water is off and the tap is open?
  6. R

    Combi Boiler Gas pressure issue - Valliant 831

    15mm gas supply, funny.............. The muppet even if he didn't notice on his site visit (How I dont know) should have in formed you when started the job. Just out of interest did you have a few quotes? If you did some of these must have mentioned a Gas Pipe upgrade and although the guy...
  7. R

    Gas supply size help

    Back on topic - CORGI bashing makes me smile. Fender. If your neighbor replaced the boiler with a modern equivalent and it was connected to her existing steel gas supply, it could void the new boilers warranty. Old steel pipework has a tendency to cause the blockage of gas valves. Pipe...
  8. R

    Vaillant system boiler 612 requirements

    Of what use is information like this? If the meter w/p is 21mb then 18mb at the appliance is not acceptable. To OP, a lot of information has to be used in order to ensure the entire Gas carcass can cope with the demands of all your alliances, some people make it sound easy; which it is if you...
  9. R

    Leaking overflow pipe; outside

    Well we cant help without a little more information. Take a look at where the pipe is in association to things inside your flat. Is it outside near boiler/toilet/or bathroom? Is it copper? Is it white or grey plastic? Hope this makes it a little more clear as to the info we need.
  10. R

    unable to buy parts without a corgi ticket horaaayyyyyy

    Wolesley are introducing this as a group. It was mentioned in a recent issue of the Gas Installer magazine, but this is NOT AN industry wide initiative. Afraid you are miss-understood my friend.
  11. R

    Wiring Hallway and Stairway Light Switches

    Ok Pics up, slight banned hosting site issue.
  12. R

    Wiring Hallway and Stairway Light Switches

    Thnx for replies guys Adam sort of got what you were saying, but there is no neutral coming from upstairs cicuit -( I think ) Anyway here is some pics. Could really do with a fools guide to sorting if possible. No Landing or Hallway lights for a couple of nights now; missus will be...
  13. R

    Valiant Boiler F23 Alert!

    Ahh beat me to it just dug out my spare instructions. Like he said :)
  14. R

    Wiring Hallway and Stairway Light Switches

    The wiring was done incorrectly before i arrived here it has never worked as i now want it to now. In the case of my setup being incorrect i have already already sent a 3 core from my Landing light to the switch on the landing in order to replace the single core switched live. Hmm on...
  15. R

    Wiring Hallway and Stairway Light Switches

    Okies Tradesman in need of help in his own home. I have a switch downstairs in my Hallway 2 Gang which i need to make switch on both my Hall light and my Landing Light. I can make this switch the Hallway easily, what i am failing to do is swich the Landing light on/off from downstairs...
  16. R

    MODENA 80E FAULT

    Do you have a set of instructions? If not call Ferroli and they will send you a set. The boiler is of the combination variety and so running the hot water has nothing to do with if it will/willnot light for Heating, infact running the Hot Water will cancel the Heating Operation for 3mins...
  17. R

    MODENA 80E FAULT

    Little more info would be nice, cant really help on this info TBH. Do you have a room thermostat? Is it turned to max when you expect the rads to heat up? Red flshing light i think the boiler is in stanby mode when it satisfied that the Central Heating is up to temp. Do you have a...
  18. R

    i`v taken the plunge

    While your chasing your arse on a non-profitable job, your more than likely losing out on a profitable one, a wise old plumber once told me. I suppose he meant don't just take a job because you have nothing else on, something good will come along.
  19. R

    Water from a vent pipe

    Can i add to my post count as well plz!
Back