  1. S

    New boiler install with low gas pressure

     Though they should have issued a "Not to CurrentStandards" notice regarding the low pressure.) On a (probably more modern)boiler requiring a burner pressure closer to the inlet pressure then low inlet pressure could cause an incorrect gas mixture and incorrect combustion which would be a safety...
  2. S

    Flue help for Vaillant combi boiler

    I think you should look.at having the boiler moved. You cant have flue pipes external. All flue joints need to be accessable for inspection. And terminal needs to be 500 mm from wall. Get a qualified installer to look at it. I would have you boiler moved into the main loft.
  3. S

    whos clued up on old baxi back boilers?

    The fires are visually the same. Its the back boilers that are differant. The fire is made for a newer model BBU. So the 552 needs the adapted version of the fire. They dont manufacture the fires now. But you can still buy them new. Check the gas council numbers. You need 37~075~04. If its the...
  4. S

    whos clued up on old baxi back boilers?

    The VP3 will not fit the 552. You need the Bermuda VP3 Renewal GC no. 37~075~04. It is same as Vp3 but modified to fit the 552, as it is a older bermuda design
  5. S

    thermostatic mixer shower

    There should be a pressure regulator fitted to the supply to your unvented cylinder. Connecting there should give you more of a equal hot and cold pressure.
  6. S

    Vokera Linea 28 hot water issues and presure drop

    Do you notice if pressure shoots up fairly quickly when boiler working on pressure guage
  7. S

    Air and F&E level

    Is the cold feed pipe connected between the vent pipe and pump?
  8. S

    hot water cylinder may be too small :(.... advice needed pl

    You can fit flow restrictors in the shower outlet
  9. S

    glowwarm space saver 50 mk 2

    Does the pilot flame reach the thermocouple tip
  10. S

    Is this the right place for the Central Heating Thermostat

    It would prob be better on the landing
  11. S

    'Pump Overrun' and 'Fan post-purge'

    Overrun is pump overrun which keeps pump running for 5 mins. And fan purge runs to get any products of combustion or unburn gas out which can be acidic
  12. S

    System pumping over after Trv and sys balance

    Where does the vent pipe to the f&e tank tee onto the system
  13. S

    glow worm 18hxi f10

    central heating return thermister fault
  14. S

    Pipes (Not) Of Peace!

    some trv need to be on flow side of rad
  15. S

    Your chance to laugh and point: Combi bashers unite!!

    the 30 maybe bit too big, maybe a 28 or 24junior would do, alot smaller, still give good flow rates and bout 200 cheaper
  16. S

    Air being vented into Open Vented CH system, advice

    maybe replacing the air sep for nwer one, of using the H wud work. i usually take the one u have out
  17. S

    Gravity system - water from vent pipe into F&E tank!

    u can get pumping over if the vent isnt high enough over the tank water level, at least 18 inches
  18. S

    Glow worm Flexicom 30CX Error code F4

    the pipe need protecting from frost with insulated lagging, on making condence pipe bigger size