    Air being vented into Open Vented CH system, advice

    what about the height of up F and E tank, the height shud be in relation to pump power
  2. S

    Air being vented into Open Vented CH system, advice

    that is a air separator designed to remove air particals. corrosion ans sludge from system maybe blocking cold feed. how high is tank in loft in relation to air sep and pump. u need a good height to give the neutral point
  3. S

    How should a pump be fitted?

    make sure the vent to the tank rises a minimum of 18 inches above water level
  4. S

    Pressure fluctuation on combi boiler central heating

    the expansion vessel cushions they increase in pressure when system gets hot, the pressure shud rise around 2 bar. if there not air charge in it the pressure will shoot up to 3 bar which will cause the pressure relief valve to open and discharge water pressure out side, which wud leave the 0.5 bar
  5. S

    Worrying boiler problem

    it looks like it piped up strangly, with the tee before pump.
  6. S

    Unexplained spasmodic gas central heating problem

    also do all ur radiators have trv,s on
  7. S

    Worrying boiler problem

    can you post any pictures,
  8. S

    Unexplained spasmodic gas central heating problem

    you have a s-plan, which uses two valves, one controled by cyl stat and other room stat. there shud be some sort of by pass on pipe between pump and two valve. if non this may create ur noise problem.
  9. S

    Unexplained spasmodic gas central heating problem

    when C is displayed, and blue light is flashing this means boiler has reach temp, and is standing by when water temp drops to light up again
  10. S

    Unexplained spasmodic gas central heating problem

    what kind of valves do u have?
  11. S

    Gas Emergency Engineer but want CEN1 etc

    u can contacy there academies directly, or on the academy web site, there on in basingstoke and dartford. not sure how much they charge, also most local colleges have construction cources with acs centres
  12. S

    Gas Emergency Engineer but want CEN1 etc

    apparently independent engineers can use british gas academies to achieve quals, as they all have acs assesment centres in them.
  13. S

    Grundfos pump horizontal or vertical?

    i put then vertical, but can go horizontal as long as it points downward slightly to stop air seizing it
  14. S

    Pressure fluctuation on combi boiler central heating

    you lost the charge in the expansion vessel
  15. S

    New loft conversion causing heating problems .....

    yeah the big silver cap, unscrew with a rag under, abit of water will come out
  16. S

    New loft conversion causing heating problems .....

    have u taken cap off pump and checked it spinning
  17. S

    New loft conversion causing heating problems .....

    header tank prob isnt high enough at least half metre above highest part of system
  18. S

    Worcester Greenstar 12i Condensing System Boiler

    he need check size of pipe and that it protected from frost and also it terminates properly, details are in installer book.
  19. S

    CH Pump Bleed Screw Sealing Washer - What Size?

    ptfe tape will seal it, works for me all time
  20. S

    Radiators not heating up is it the pump or a blockage?

    u got enough system pressure, the pump auto vent open, and pipes in loft lagged