  1. D

    Lighting help

    I sometimes wonder why I bother with this forum, I didnt ask for advice on each aspect of building control - but I appreciate your concern in helping me find some lights that dont contravene building regs. You may notice I said I dont want to use traditional downlighters, this is because the...
  2. D

    Lighting help

    Only £30 each?? You might consider that cheap at london prices, but given I can get a spotlight for around £3 quid from a local wholesaler I'd say these are considerably more.. Anyway dont make the assumption that because the house is renovated and extended that I had a massive budget. I...
  3. D

    Lighting help

    I've recently built an extension to the house Im renovating and would like to do the easy option and stick spotlights in but due to the insulation and looking a building control guidance notes this could be a little bit of an issue, everyone suggests I could get away with it or throw the wires...
  4. D

    Flush Wall Mounted External PIR

    Ignore the where are they from comment, I looked at the URL of the picture and then searched STIS180S David
  5. D

    Flush Wall Mounted External PIR

    Hmm I like the sound of plan B, and dont know why I didnt think of that! Ill go look and see if I can find any brick style wall lights with PIR's now! Where are the ones you pictured from?
  6. D

    Flush Wall Mounted External PIR

    I'm wanting to descretely mount a PIR in the side of a garden wall to switch some lights on, does anyone know if such things exist? I dont really want to mount a conventional type in an alcove as it will look a **** really. Im not really bothered what switching capacity it has as I can use a...
  7. D

    Earthing question.. (arent they all?)

    Cheers, will check it out tomorrow when I have my red book to hand. No livestock in one barn.. other has some stables in it, bonded all steelwork up at the weekend with 16mm² Earth cable.. David
  8. D

    Earthing question.. (arent they all?)

    Your saying that I can use the Earth in A so long as I bond the steelwork in B (Which goes without saying!) and assuming the cable CPC is ok for the maximum fault current (likely to be a 4core 25mm² at the moment) then it should be ok. David
  9. D

    Earthing question.. (arent they all?)

    erm yeah.. :oops: Embarrasing mistake :o
  10. D

    Earthing question.. (arent they all?)

    I've normally only ever had to consider PME / TNC-S supplies, but what is the common practice for earthing in this scenario in a TNC-S scenario.. If you have a TP&N submain terminating in a barn with local earthrod, and the structural steelwork is bonded with 16mm² cable. Say you were...
  11. D

    Cable Size for 630A

    Length is looking more like its around 10m now, I have checked it a bit better. David
  12. D

    clip on meters

    www.ndmeter.co.uk Fit some CT's to the tails, and add the meters in a din rail enclosure. David
  13. D

    Tails in Cavitys

    If each tail ran in a 25mm Kopex conduit, which were glanded into the meter box, would this be allowed?? David
  14. D

    Cable Size for 630A

    Pretty big cable required then, certainly bigger than 2x95mm²
  15. D

    Cable Size for 630A

    from this: to this
  16. D

    Cable Size for 630A

    Well the cable size they think will do it is 2x 95mm² (From the existing genny) which was 200Kva or 220.. David
  17. D

    Cable Size for 630A

    Easy and Hard I guess, otherwise I'll never know!
  18. D

    Cable Size for 630A

    20m Max. Supply cable from a TP+N Genny 440Kva + 10%
  19. D

    Cable Size for 630A

    What size cable and CPC is required for 630A? SWA Laid on cable basket / ladder rack - No other cables present. Rating for PVC and XLPE would be nice.. Just wanting to sanity check someone elses calcs. David