  1. D

    Galv. Box trunking, protecting edges around openings?

    Thats also what the sparkys have recommended, as I have asked them to fit the Galv trunking.. We dont have time. They have used paxolin (sp) between the MCCB board & the 2x 24way TP Merlin Gerin Boards.. David
  2. D

    Galv. Box trunking, protecting edges around openings?

    Cant do that the opening needs to be around 540mm Idea we are swinging towards is removing most of the side of the trunking, and just spanning the gap with the lid. Will sort some pics to explain.
  3. D

    Galv. Box trunking, protecting edges around openings?

    Its to go under a phone system, Theres around 16x 20 pair cables to come out along the length. What I'll probably do is holesaw each end and then jigsaw it out.. T&E would probably work well, but would look a little rough, even though it would be effective.. Ill get some of the grommet srip I...
  4. D

    Galv. Box trunking, protecting edges around openings?

    Wish I could use a T however the opening needs to be around 560mm Long! David
  5. D

    Galv. Box trunking, protecting edges around openings?

    We need to intall something at work, and rather than using 100x100 PVC Trunking, I'd rather use 100x100 Galv trunking so that it matches the existing stuff, However I need to cut an opening in it for cables (Telephony / Data) around 550mm long however I dont want the edges getting damaged...
  6. D

    SwitchFuse or DP isolator

    When I say DP Isolator I mean such as a 63A Main Incomer type or am I missing something funamental here?
  7. D

    Drilled through cable

    Dunno if a consumer unit counts as an outlet?
  8. D

    SwitchFuse or DP isolator

    If running an SWA (say 16.0mm²) to an outbuilding, would you protect it via a switchfuse (~63A) or a DP isolator in an enclosure? Whats your preference, previously I've used the metal clad Wylex Switchfuses, but just wondering. David
  9. D

    Cabling for gate opener

    Perfect for thieves to plug in their angle grinders.. Hence why all my outdoor sockets are supplied via FCU's! And yes I know you can get cordless or a nice quiet gas axe.. Paranoid? Me? Nah..
  10. D

    200Kva Generator

    start at over 6k.
  11. D

    200Kva Generator

    Anybody interested in purchasing a 200Kva 3 phase generator? Very little use, made by SDMO.. Fairly cheap, Located in Leeds City Centre.. Can arrange for it to be dropped onto the back of a truck / trailer / allports wagon via crane if it ties in with removal dates. David
  12. D

    Has anyone got a pic of a 3 phase CU

    Damn right.. its bad enough messing around with live tails ;) So next time someone says can I get 2x 4mm² or 2x 6mm² singles into a socket, we can safely say that you can actually get 16mm² or even 25mm² cables in :D ;) I suppose the difference is when I do a rewire, its on a refurb, so we...
  13. D

    Has anyone got a pic of a 3 phase CU

    Sorry for the delay in replying, I havent been to college, As Im not a qualified electrician, but NO Way would I dare do that.. I have a Baby CU mounted to a board with some rope to form a handle for the board. Mounted on this is a henley block and a double socket, the CU contains an RCD and...
  14. D

    BT to CAT 5

    http://www.surrey.ac.uk/eng/Intranet/ict/support/UTP.HTM
  15. D

    Has anyone got a pic of a 3 phase CU

    is the socket on the left really connected how I think it is? David
  16. D

    wiring spotlights

    Right then.. junction box through the hole it is then.. strain releif needed on T&E pah ;) You'll be suggesting I use cable clips next!
  17. D

    wiring spotlights

    Yeah they are GU10's I thought about the switch method, but dont really want to bring the neutrals into the switch patress, call me picky!
  18. D

    wiring spotlights

    Quick theoretical question, If using 1.5mm² t&e how do you wire spotlights? I know 1.00mm² is a little easier to get in, however IE junction boxes need to be accessible, so where do you do what you would normally do in a ceiling rose? David
  19. D

    Wiring a cabin

    I cant quote the regs but that sounds bad to me.. use black 4" waste pipe -no cable marking tape and someone cuts the pipe with a stihl saw to add a drain.. Spend the money and buy proper cable ducting. David
  20. D

    UPS Overload... RCD Breaking

    How many KVA are the UPS's? What are connected to them? Do the UPS report any overload's, brownouts etc in the logs? David