    Baxi Combi 80 Eco DHW Problem

    Hi, yeah, Ive checked it again, and the PCB knobs are "zero-ed" in. Its the other two smaller components on the back that im interested in, these obviously must control something, but im not sure what, Thanks, Stef
  2. S

    Baxi Combi 80 Eco DHW Problem

    Hi, another baxi problem.... Does anyone know what the two "adjustment terminals" are for on the back of the PCB? They are both labelled P£ min and P4 max. Im under the impression that these are for adjusting the temperature, and I may have moved them, So does any one know what position they...
  3. S

    Baxi Boiler 80 eco

    Dont mean to sound stupid, but you definately have closed the filling loop yeah? That to me would be the only thing that would make the pressure increase?
  4. S

    Problem with my lighting circuit!

    sorry for the confusion, shed, I was installing it the other day, I do actually hold a 2391, i just couldnt find my mistake, the "pendant" to the downlighter bulb, has two blue wires, hence my confusion
  5. S

    Problem with my lighting circuit!

    Yes!!!, Halillolya!!! Your were right, see this is why your supposed to sleeve all cables, in the first fix!!!!! :) thank you!!!, you've made my day!
  6. S

    Problem with my lighting circuit!

    Engstudent, you maybe right, i'll be back in less than 3 mins!!!!
  7. S

    Problem with my lighting circuit!

    stef99 wrote: yeah, i have - twice, I also diconnected all the earths just to see if I had gone through a cable when putting the boards back, and its still the same? Can you run me through your thought process on this? icon_confused.gif Back to top i was to make sure that i didnt...
  8. S

    Problem with my lighting circuit!

    ok, i tried that, and disconected to bulb altogether in the last working light, and the circuit goes dead after this light, which means that the other lights litterally rely on this light being powered to use the remaining lights, im gonna have a think about this and draw a picture right now, do...
  9. S

    Problem with my lighting circuit!

    yeah, i have - twice, I also diconnected all the earths just to see if I had gone through a cable when putting the boards back, and its still the same?
  10. S

    Problem with my lighting circuit!

    Hi, ok, i'll try to keep this short. My radial lighting circuit (6A) is acting up, its the first time i've come to test it the circuit runs to my 2 way switching, then to the living room and then to the kitchen and the utility room. I have two downlighters powered off this circuit (for...
  11. S

    2 Gnag Intermediate light Switch?

    Thanks thats excellent, I'll be trying contactum... as for the grid system, there expensice CEF were gonna bill me £14! for a double switch!?
  12. S

    Mains Powered Smoke Alarms.

    Hi, Im thinking of getting some mains powered smoke alarms for my place. They may not be part of the regs, but I'd like them for piece of mind and to look posh... Im after the Kidde brand as I used to work with them all the time (Kidde Fynetics) However I've been told that these are now...
  13. S

    2 Gnag Intermediate light Switch?

    Hi, I only have space to add a double intermediate switch in a space, All the other recepticals are crabtree, and I woundered, is there a switch I can use here? I also want to avoid the grid systems, neither MK or crabtree. Im sure I've seen these around somewhere, but cant place it? Can...
  14. S

    Baxi Combi 80 Eco DHW Problem

    Thanks for your reply, Im quite surprised that the boiler uses the central heating pipes to heat the domestic hot water, but maybe thats what the second heat exchanger is for. So just to claify, when you turn on the hot tap, it automatically starts to heat the radiators, but then diverts...
  15. S

    TN-S and TN-C-S

    Hi, can someone tell me how to tell the difference in this in real life? if the earth goes to the armoured sheathing then its TN-S but how do you identify a TN-C-S system?would there usually be a separate earth going down the main incomer with the live and neutrals? I've heard that if the...
  16. S

    Baxi Combi 80 Eco DHW Problem

    Hi, Im new here, so I will try and keep this brief... I have flushed my DWH heat exchanger twice, both times with a pressure washer and all sort of weird chemicals, However, my hot water only stays hot for about a week or so, and then it get clogged again. So my question is... If i...