    The fence would need to be a permanent structure - not a flimsy wooden thing :) Do you mean attach the cable to the concrete posts with no support in between? What distance apart are the posts? If burying the cable is not possible what about using a catenary wire? PartP will mean this...
  2. T

    Running cables in loft - can I do this?

    Agreed drilling holes randomly can be bad for joist strength.... OSG recommends (non armoured) min 50mm from top or bottom of joist and max diameter of 0.25 x joist depth. They should be on centre line between 0.25 and 0.4 x span of joist. Holes in same joist should be 3 diameters apart.
  3. T

    Instant messaging

    People may have been thinking more along the lines of something like Triton - a free web based chat app - plenty of others that could be used as well....
  4. T

    Instant messaging

    MSN in my profile :)
  5. T

    Instant messaging

    For one specific topic chat (eg Electrics) it wouldn't be the perfect platform but to bring the whole of DIYNOT together as more of a community it may have some benefits?
  6. T

    Short Spurs

    Practice flipping through the reg index faster - that would improve your scores ;) On a similar note I have a human created index for the regs which is much more intuitave if anyone would like a copy?
  7. T

    Instant messaging

    Agreed with RF - however I have seen a who's online/chat addon to some forums where you can talk in the chatroom attached to the forum as an added extra
  8. T

    Can I bond radiator underneath floor board

    I've heard of this but never seen it implemented - has anyone actually ever done it this way?
  9. T

    Is this correct????

    Danger is that the fuse is now on the neutral - could lead to a nasty situation if theres an earth fault to the casing of the plugged in appliance
  10. T

    Lights go out intermittently

    Like you mentioned I would be checking for bad/burned connections etc
  11. T

    Electrics UK 3rd Birthday on July 15

    that's your girlfriend?...the two timing b!t$h
  12. T

    bathroom pull cord lighting switch

    If you can't fit it in the batroom you'll need a switch in the hall by the door - is there no space in zone 3 for the shower?
  13. T

    bathroom pull cord lighting switch

    How high is the ceiling? Could you get it above 3m and in zone 3 for the shower?
  14. T

    Electrics UK 3rd Birthday on July 15

    I made a lovely cake....but got ermmm carried away on the tasting...feel free to share what's left amongst yourselves :oops:
  15. T

    bathroom pull cord lighting switch

    What size is the bathroom? Have a look at this diagram - the pull cord can only be in zone 3 or outside.... EDIT wrong diagram but will keep this here for info
  16. T

    Earth wire conduit

    Cold chisel and club hammer would do - use eyes to check for existing cable/pipe runs (horizontal and vertical from sockets etc) - could also get a stud/cable detector but not always 100% accurate!
  17. T

    Is earthing sockets to their casing dodgy?

    I've used a fair amount of FP and it's definetaly 100x easier and quicker to work with than MI cables - I thought most would use these for fire alarm systems these days except perhaps where Pyro or the likes would offer better protection or for neater surface work(?)
  18. T

    Is earthing sockets to their casing dodgy?

    Was Pyro not just a shortened version of Pyrotenax - the company that manufactured it?
  19. T

    wiring up a steel joist

    No bonding required - this is in your house right?
  20. T

    Which 2way dimmer to operate 15 mains halogen spots?

    Might be best to split them into alternate lights controlled by a 2 or 3 gang switch instead of using a dimmer?