    Boiler help/advice

    Isolation valves. Recently had to isolate said valves under my Vaillant Ecotec plus 832 to remove a radiator from the system. Used Allen key to turn the spindle quarter turn with some difficulty. After the radiator was drained and removed, pipes capped, when I returned to the boiler, pressure...
  2. D

    yet another boiler losing pressure thread

    Do a search, you will find plenty on that topic
  3. D

    Potteerton boiler

    Potteerton. Not heard of this brand
  4. D

    Method or madness in this CH installation?

    I suspect boiler is a Vokera Maxin 24 or 28. It does. Is fitted in the diverter valve My suspicion is the boiler lacks proper system balance and if there is no room thermostat, installation will benefit if one was added. Certain parts may be difficult to get though some parts are Vokera items...
  5. D

    Trump v Zelenskyy

    Bone spurs trump
  6. D

    Musk on drugs

    Wonder why then the MODS said abusive post removed or did I misread.
  7. D

    Musk on drugs

    Top of your post says abusive post removed. Public forum, why the abuse.
  8. D

    Has wrong kW rated boiler been fitted

    Do you know combi boiler operation? I would love to see a combi provide 60 degrees of hot water at stipulated flow rate let alone 70 And where does legionella come in, this is a combination boiler that heats water you drink- no stored water here A combi will heat cold water by35 degrees a flow...
  9. D

    DOGE gets kicked in the nuts

  10. D

    Any truth in this msnbc clip?

  11. D

    Ideal C35 Running Cost

    C35 is a 35 kW combi boiler. When running a hot tap, it will fire at 35 kW and then modulate to maintain temperature. For heating multiply each radiator by 1.5 to guesstimate the load on the boiler- doubt it will come to 18kW even. Do you have a room thermostat or relying on TRVs to regulate...
  12. D

    Imperial radiator size (690mm) with new rads

    I have always believed women can do the same job as men, sometimes better so question for you is, how do you intent tackling this task You are going to have to fit the new radiator such that the valve tails line up with the existing pipe. Double panel will cause problems if pipes have no...
  13. D

    Heat Electric limited

    Daughter has one radiator that shows red light indicating demand active, integral pump running but no heat. Any help to get it working will be much appreciated
  14. D

    Heat Electric limited

    Any of you chaps involved with this companies water filled electric radiators?
  15. D

    Sulphuric acid

    Plunger creates pressure in the drain pipe Have the openings and branches been sealed so that the pressure created by the plunger will act on the blockage?
  16. D

    Vokera linea 28. Error 04, water pressure OK. Micro switch is not pressed.

    Now you see why I was asking for that specific information. Attended a Baxi 105e boiler. Heating worked ok because heating side has greater resistance so flow manifold ( spindle in your text) operated no problem. During hot water demand, the spindle pushed out half heartedly but did not...
  17. D

    Vokera linea 28. Error 04, water pressure OK. Micro switch is not pressed.

    Actuator motor has nothing to do with 04 fault code If the pin moves then pump is moving. Your info re 04 during heating and hw is sketchy in that solid information is needed which is what the heating engineer acquires while in front of the boiler. My suspicion is that HW demand is resulting...
  18. D

    Vokera linea 28. Error 04, water pressure OK. Micro switch is not pressed.

    One has to appreciate boiler mechanics to understand what is happening in your boiler. The pump creates pressure difference in water ie negative at the inlet and positive at the outlet. This difference is seen by the manifold with the microswitch indicating pump is running and there is water...
  19. D

    Vokera linea 28. Error 04, water pressure OK. Micro switch is not pressed.

    Is the air evacuated from the boiler. Is the pump running Happening for heating and hot water also?