Search results

  1. B

    Cavity wall insulation requirements

    That's one of the things I was wondering about. Is there a rule about footing width v wall width? You can build a wall offset on a foundation so presumably there isn't a minimum spacing to footing edge? We will need clay board so potentially looking at a 700mm trench which I guess is another...
  2. B

    Cavity wall insulation requirements

    But easier than a 150mm cavity?
  3. B

    Cavity wall insulation requirements

    This stuff? https://unilininsulation.co.uk/products/cavitytherm/ Appears to be PIR like Kingspan with a textured surface to aid drainage on the external face?
  4. B

    Maximum thickness of mortar bed joint.

    When I've needed to build up a bed I've used a sharp sand mortar for the first course - doesn't slump and stronger than a soft sand mortar.
  5. B

    Cavity wall insulation requirements

    Hi All What is the standard wall detail with the new part L requirements please? I have a 2021 design with 100mm cavity bats and thermalite inner skin. I understand that's no longer enough? I guess the three options are: 1. 150mm cavity with rockwool batts 2. 100mm cavity with Kingspan 3. EWI...
  6. B

    Outdoor Fixing for Green Oak

    I don't understand. What's an oration? I linked to the screw size above.
  7. B

    Peelaway 7 - turned into Smearaway

    I've not used Peelaway 7 but have used Peelaway 1. It partially dried, like a cracked toothpaste. Some came with the bandages but there was still a lot to scrub off.
  8. B

    Outdoor Fixing for Green Oak

    https://www.screwfix.com/p/easydrive-hex-bolt-self-tapping-coach-screws-8mm-x-100mm-10-pack/2417T?kpid=2417T&cm_mmc=Google-_-Datafeed-_-Screws%2C%20Nails%20and%20Fixings?kpid=KINASEKPID&cm_mmc=Google-_-TOKEN1-_-TOKEN2&gclsrc=ds&gclsrc=ds I would use an 8mm clearance hole in the beam and a 5mm...
  9. B

    Painting plywood with raw edge

    Oh and I've looked at faced plywoods (phenolic or melamine) but they're cost prohibitive, around £200 to order a single board. A shame as they would be the perfect solution.
  10. B

    Painting plywood with raw edge

    I would like to make some furniture from plywood. I plan to leave the edge raw (clear Matt varnished) and the faces painted. Any tips on how to get a good finish? I will roller the faces using a short pile gloss roller. Would masking be sufficient to get a crisp edge? Or would you paint the...
  11. B

    What are these in every room

    As per one of the first comments, likely to be old storage heaters or electric radiators.
  12. B

    Repair buckled wood floor

    Hi, I have an engineered maple floor, full glue down, with 150mm wide boards. Two boards have buckled in a little pyramid. They are at a doorway. Lifting the threshold it looks like the boards and glue have pulled the self levelling compound away from the floor. I have an offcut but not...
  13. B

    MCS Rule - Homeowners Present

    Plus a days labour for two roofers and an electrician. Another £1500?
  14. B

    Access plug into boss

    Yes exactly.
  15. B

    Access plug into boss

    Thanks all, I managed to find a Polypipe stockist locally and got a solvent bush. We got a drain snake up to the toilet and pulled out sanitary products. Lovely!
  16. B

    VW rear USB no power

    Hi, I have a Sharan 7N but believe this is a common set of parts across VAG including Golf Mk7 so hopefully more commonly known! The centre console has two rear USB ports for 2nd row seats, powered from a red plug. I can't find this plug in the wiring diagram (page 1/14). There is no voltage on...
  17. B

    Access plug into boss

    Ah ok thanks. I thought a boss was 2" so pipe would go straight in. Are they some other size like 2.5"? Or non standard sizes since manufacturer specific?
  18. B

    Access plug into boss

    My friend has a recurring toilet blockage. I plan to go up and help him fix it soon. From pictures there is a helpfully located soil boss/junction that I planned to hole saw into and then try rods/snake and my endoscope camera. I asked him to buy one of these and test fit it. He says it's too...
  19. B

    32A Industrial socket for cooker?

    I thought BS7671 said that heating appliances over 2kw and any appliances over 3kw should be on their own circuit?
Back