  1. vulcancontinental

    Which boiler for our house?

    I didn't catch what you have at the moment, is the new system a complete new system? you have four opinions at the moment but ask for more to clear confusion when more options and opinions may or not help. I'll stick my oar in. If you have a CW storage cistern in the loft and a hot water...
  2. vulcancontinental

    GAS ENGINEER REFUSES TO REMOVE old BOILER

    What boiler? There's a list of boilers containing asbestos on the HSE website and instructions on how to safely remove and bag the asbestos then hope your local tidy tip accepts it, some don't.
  3. vulcancontinental

    Notification of installation of a fixed heating appliance

    With a gas appliance, say a combi boiler change; upon completion the installation is notified to Building Control as being installed to and complying with the prevailing regs by the installer who, being Gas Safe registered is deemed a competent person. Would an electric boiler require notification?
  4. vulcancontinental

    Notification of installation of a fixed heating appliance

    As title. I had the discussion the other day and was told a fixed electrical heating appliance such as an electric boiler does not require notification. I believe it does. Am I incorrect?
  5. vulcancontinental

    CH Energy Requirements Estimate

    Mid terrace is good unless neighbours are a nuisance somehow. First floor in three storey buildings better still. That's not what the op wants however. Heat-Engineer and use the estimator not the in-depth survey option. Close enough or if the ceilings are not too high use L x B x 100 = watts
  6. vulcancontinental

    Injector missing from boiler - is it dangerous?

    Just be glad it was a 40, the over gassing would have been greater if a lower output.
  7. vulcancontinental

    Heat Loss Calc For Heat Only Boiler

    Get another heating engineer or do it yourself if you have time and a tenner. Use Heat-Engineer software. You'll spend a day but you'll have an accurate heat loss calculation.
  8. vulcancontinental

    How to wire Vokera Unica Max S with PDHW & Weather Comp

    Yes, there's a relay included with each system boiler that allows switching to WC flow temps when DHW stat is satisfied. I don't have the diagram here but a call to tech should be able to source one.
  9. vulcancontinental

    Twin Flu

    Vokera Vibe Max; actually any Vokera but the other models may be physically too big, the Vibe Max is a cupboard fit.
  10. vulcancontinental

    Sabre 35 he plume kit question

    You've probably got the older metal flue but the add-ons I believe should still work. Vokera part 20142842 plume kit or 20142841 45 degree plume diverter. Tell her the flue consists of CO2 that plants convert to O2 and H2O which plants need to survive. The condensate is slightly acidic so...
  11. vulcancontinental

    Flue pipe removal

    I would say I have no doubt that flue is asbestos. Depending on your local authority they may accept it double-bagged and sealed at the local tidy tip, some will not and reject it out of hand. You need to wet it, remove it without breaking it or creating dust then use the correctly labelled bags...
  12. vulcancontinental

    Urgent boiler replacement

    Personal opinion: keep cylinder existing or replaced, flush heating system, if there isn't an immersion heater in the cylinder take the opportunity to get one fitted, replace boiler, straight swap, easy. Any boiler is 20% hydrogen at the moment and hydrogen is currently being injected into the...
  13. vulcancontinental

    Diverter valve cartridge vokera unica 28he

    Parts do have a habit of changing numbers. Ring spares but I think you have the second version. The cartridge you see for the Lines One is the same across the ranges, they might give a different number but I'm sure that's the one.
  14. vulcancontinental

    Diverter valve cartridge vokera unica 28he

    Yes, there were changes in the design. You could also ring sales 01727 744000 with the serial number
  15. vulcancontinental

    Boiler Suggestion - Small 24Kw

    Yes, I've used Nest ON/OFF and opentherm with the Vibe Max 26C
  16. vulcancontinental

    Ideal Vogue combi. Range rating, or the lack of ......

    I hope you'll bear with us otherwise we're swapping between threads to find older posts.
  17. vulcancontinental

    Ideal Vogue combi. Range rating, or the lack of ......

    It's tricky to set up weather com because of the above and there are calculations made on the weather data gthat slow things down. I think I'll simply lock the boiler stat to 45 and restrict the flow through the boiler to raise the return temp because if the return is cold then the boiler just...
  18. vulcancontinental

    Ideal Vogue combi. Range rating, or the lack of ......

    I just did a couple of videos, one with and one without WC but I can't emulate a house ticking over. Our test rigs get rid of the heat through a plate heat exchanger so it's like a range rated 8kW combi trying to heat hot water therefore the return is so low the boiler is always running at an...