    Mains bell/sounder in conjunction with PIR floodlight

    Thanks for your suggestion. I had the local police security person here yesterday to look at our security arrangements and was advised that having a light/s coming on was no deterrent especially as we are very remote here and the house is 100 yards from where the office building is that needs...
  2. C

    Mains bell/sounder in conjunction with PIR floodlight

    I have a remote property that I've fully alarmed but I now am turning my attention to exterior PIR floodlighting. When particular lights are triggered I want them also to trigger an alarm bell/sounder for two reasons. 1. To let me know that someone is where they should not be. 2. To...
  3. C

    PIR for external position

    Many thanks for your suggestion. Cheers Richard
  4. C

    PIR for external position

    I want a reasonably priced PIR that I can use in conjunction with my Scantronics 9651 box and is suitable for looking at an external wall area of about 10m length which has two vulnerable windows. These windows are alarmed but I want the alarm system to trigger when someone intrudes into this...
  5. C

    Wiring a Masterblaster siren to a Texecom Odyssey alarm box

    My apologies for the delayed reply but I've been away from home and my thanks for your advise. Can I make those connections into the existing sounder box or must they be made directly into the control panel? Ideally I would connect the two wires into the sounder box as I do not have any...
  6. C

    Wiring a Masterblaster siren to a Texecom Odyssey alarm box

    Thanks for the info. Yes I want to put off anyone even thinking of breaking in. When running in the alarm cabling a year or so ago I also ran alarm wires to various outside walls along with power cabling and security camera wiring. I wanted to have all bases covered in case I felt the need...
  7. C

    Wiring a Masterblaster siren to a Texecom Odyssey alarm box

    Thanks for giving my difficulty further thought. I did not mention that I've already got a Blaster type siren to go inside, so that if anyone actually gets into the building they will get such an earful they are not likely to stick around for long.....the noise will be devastating! To fill...
  8. C

    Wiring a Masterblaster siren to a Texecom Odyssey alarm box

    The building is an old stone barn with a slate roof with a height to the eves of about fifteen feet. The alarm box and Blaster are fixed to one of the side walls just under the eves for proction againt the elements. The wiring is all concealed and enters from the back. The blaster is the...
  9. C

    Wiring a Masterblaster siren to a Texecom Odyssey alarm box

    Would this be the case with all PIRs? I would be trying to protect just this small area of wall on which the alarm box and Masterblaster are situated.
  10. C

    Scantronic 9651 adding new users

    Thanks, I remember reading this but cannot think what combination I used but would have expected it to end in a 2 ! Cheers Richard
  11. C

    Scantronic 9651 adding new users

    Thanks for that. Managed to get the fob recognised and it works! Thought I had better see if entering the user code manually worked in case I mislaid the fob but it failed. I'm sure I had entered 000002 for user 02. Back to the drawing board<G> Cheers Richard
  12. C

    Scantronic 9651 adding new users

    Thanks for our assistance but I just do not follow so can you take it more slowly please<G> I've read all that is in the manuals and still cannot get it! Many thanks
  13. C

    Scantronic 9651 adding new users

    Guys this is driving me nuts! I've changed the access codes from 4 to 6 digits and the master user to a new number. Now I want to set up a new user (me) and then assign it to work with a proximity tag but am hitting a brick wall. I've read the User Manual and the Installation and Programming...
  14. C

    Wiring a Masterblaster siren to a Texecom Odyssey alarm box

    As a follow-on from my earlier question is there any way to protect against interference with the Masterblaster? It and the alarm box are situated high up on an outside wall under the eaves. I did wonder if fitting an exterior PIR to protect it might be the solution. If so how would I wire...
  15. C

    Wiring a Masterblaster siren to a Texecom Odyssey alarm box

    Many thanks for the info and yes I am aware that the siren needs mains power as well. Cheers Richard
  16. C

    Wiring a Masterblaster siren to a Texecom Odyssey alarm box

    I've installed a FSL system using a Scantronics control box with a Texecom Odyssey alarm box on a four wire cable with the siren and strobe connected together. I've now added a Materblaster siren next to the alarm box to up the noise level (we are very remote here) and would appreciate advise...