Search results

  1. P

    greenstar 30cdi stuck in purge mode?

    This happened to me after I put one into service mode to check ratio. Couldnt get it out again even after level 2 reset. Was still under warrenty (just) so got Worcsester out and they changed the board. Stan
  2. P

    Response gas pressure problem (UPDATED)

    UNLUCKY :!: :D Never mind you will never be out of a job. Stan
  3. P

    Ocean Combi, DHW flow... not

    It obviously IS the diaphragm as you are only getting hot water because you have turned the heating on :!: The fan resistor is hot as it is disapaiting heat from the reduction in voltage for the low fan rate which this boiler requires as it has a pilot light. Perfectly normal, but does...
  4. P

    Response gas pressure problem (UPDATED)

    Oh I think it is old boy :wink: Stan
  5. P

    Response gas pressure problem (UPDATED)

    I am pretty sure this it sounds like the gas valve not opening to me. Is this one the same as the Minimiser as I cant remember.Other than that just undo the inlet while isolated then open it up. You will soon know if there is a blockage. Stan
  6. P

    Ideal Response 120 - Hard to work on.

    Check the spark gap as the probes have a nasty habit of warping. Far more improtant is make sure it has the flue saftey stat fiited :!: :!: If it hasnt then tell the customer to ring Ideal pronto. They should come and fit it free of charge as its a saftey issue. Stan
  7. P

    Ideal Response 120 - Hard to work on.

    Yep nice little ring and open ended 8mm never let me down even with the Minimiser. Stan
  8. P

    My first soldered joints - how they look?

    Yep I agree aswell Dave. Have used Laco for a fair few years now and I use Kimwipe. Havent tried the old Frys Fluxite paste in a while :o Stan
  9. P

    My first soldered joints - how they look?

    :lol: and some 28mm......or 32 if you are feeling frisky. :shock: Stan
  10. P

    Question for the old timers or clever young 'uns

    Thanks both Chris's Why did I not think of just punching it in on google! Tony I know the owner was keen not to over charge as they can be had for that. This tinternet thing, just too damn clever. Stan
  11. P

    Question for the old timers or clever young 'uns

    I wish it was Dan, but I know a U6 uses .071 cubic feet per rev. I just cannot for the live of me work out how to convert it. The gas bill only provides how to get Metric calculations Stan
  12. P

    Question for the old timers or clever young 'uns

    Got a customer who is using secondary coin meters in flats and they are struggling to work out where to set the mechanisum for the amount of gas provided per pound coin. The question is how can I get a calculation from the number of units used to cubic feet per hour. I have looked at the bill...
  13. P

    'ECO' / Set-back temperature (Vaillant)

    Stops it rising above Dan :!: So it does Airconditioning aswell :D Stan
  14. P

    Vaillant ecoTEC plus 831 warmstart facility, economical?

    I have found that the best way is to obtain the optional programmer that fits in the front of the boiler. If you get the right one you can then time the pre heat facility much like the Worcester DT20 system does. This way you can just preheat at times of demand. Stan
  15. P

    CLASSIC COMBI

    From my memory which aint good this boiler has got a wax stat but I never had one go!. It works using a 3 port valve(No Mid position of course) and thermostats on various pipes. Go loads of em on an estate round here. Pain in the ass to work on as the pressure guage is located through the top...
  16. P

    worcester 9.24 pcb urgently required

    I still have one but its been in the van for about 10 years. Will have to double check its the model you want but sure it is. You are welcome to have it for the cost of postage if you like. Drop me a PM with your email or contact number Stan
  17. P

    Potterton netaheat 16/22

    You havent stipulated which MK the boiler is. There are 3 different variants of this boiler all working in a different way. Does yours actually have a PCB? Stan
  18. P

    myson midas combi

    Its got two sensors I thought one on the inlet and one in the outlet to the calorifier. My stab is the pumps stuffed. If its a Myson unit 5 its been there as long as the boiler. Great boilers apart from the SFI which was a real bitch. Who the hell designed that airflow sensor :twisted: P.S...
  19. P

    Help Please C & M Britony safety valve

    I was merely asking the question Chris. No need to jump on your oss about it. Obvously if they say its ok then who am I to argue. Just wondered why ever other blow off is usually copper. And no I havent see super heated water from a blowoff. Again it is a possibilty though and I cant see that...
  20. P

    Help Please C & M Britony safety valve

    By the way guys how come Chaff can get away with a bit of clear plastic tube stuffed on the end of their blow off. Do you think they have ever seen super heated water at 3 bar before :!: :x Stan
Back