  1. O

    firebird 120

    Or it could be the control box.
  2. O

    1000ltrs of oil in 2 months???????????

    Oilman is giving you good advice. Why don't you take it ? For starters you will need to purchase several hundred pounds worth of test equipment and then use it for several months at least with guidance from a professional to be able to sort your boiler out. If there is just a thin layer of soot...
  3. O

    Oil boiler flame intermittent

    The air intake could be sucking in fumes from the exhaust. When you take the cover of it can breath from the room, hence it runs trouble free. Trace the leak of fumes and seal it up. If its in the flue and new seals can't be obtained seal it up with high temperature silicone.
  4. O

    Frost stat problems?

    The frost stat has its own supply of electric i.e. not through the programmer. This, as you say, fires the boiler to prevent boiler and pipes from freezing (which obviously means in other words the heating comes on). You are also correct that there should be a pipe stat on the return to the...
  5. O

    Trianco Eurostar 65 not flaming

    The clue is you can smell oil. If solenoid was duff it would not let any oil through. Check ignition first, then pump pressure. If you've no idea how or lack the tools it best to get some one in.
  6. O

    Trianco Eurostar 65 not flaming

    Check ignition. i.e. spark, electrodes, leads, transformer, control box.
  7. O

    Worcester Bosch Heatlslave 12/14 pump steaming

    The "T" part of the fuse number means "time delay" so it is a slow blow type fuse.
  8. O

    Worcester bosch Heatslace 20/25 No hot water

    Yes, it's the wrong way round. Port A should go to the heating.
  9. O

    New Grant Boiler - cant be fitted in utility room????

    It may be costly for a tall vertical balanced flue but they work very well and all the flue products are dispersed at roof level instead of in your garden/alley/patio or wherever at low level. Having said that a boiler in your garage has advantages in that there is no oil in the house and the...
  10. O

    large oil supply pipe

    Hi folks, help needed please. I have been asked to pipe up from a new underground tank about thirty metres to an existing boiler down in a cellar. The boiler is a big beast of a thing with 156kw input and a riello g20 burner.I don't usually work on systems this large. The tank (5000 litre) is...
  11. O

    Grandee Heating World combination boiler

    Probably not as you have already tried the boiler with the other two switched off and it made no difference.There can't be many more parts left to change, let us know if the NR valve cures it.
  12. O

    Grandee Heating World combination boiler

    Has the motor capacitor been checked ?
  13. O

    immersion thermo length

    No loft, it's one of those where the roof spars have been filled in between with kingspan, plasterboarded and skimmed, so it looks like i'll have to lift a few tiles on the roof to get at it. Thanks for your help, STIX.
  14. O

    immersion thermo length

    the roof being the roof of the house. If i cut a hole in the plaster board above the cylinder i'll be looking at laths and roof tiles. Maybe i'll have to go in through the roof.
  15. O

    500 LITRES IN 42 DAYS

    One baffle ain't right. Should have a set of at least 3 . Only one will mean a lot of usefull heat dissappearing up your flue.
  16. O

    immersion thermo length

    Hi all, i have been asked to change an old immersion thermostat for a new re-settable one. The current one is in an immersion on the top of a cylinder. The problem is the top of the cylinder is only about 12" below the roof and when i withdraw the old stat there isn't enough clearance for it to...
  17. O

    EOGB Burner with intermittent lock out

    Have you checked the fuel filter ?
  18. O

    firebird olympic oil fired combi boiler...no heating

    Don,t think that boiler has an MV. Could be a relay, stat or timer giving you trouble.
  19. O

    FIRBIRD COMBI 90, NO HOT WATER???

    Fixed one recently with the same symptoms. It was a faulty pump on h/w side.
  20. O

    Atkinson Tankmaster Valve servicing

    Spin the valve wheel till it goes slack/loose. In this position the oil is off.Tighten up but not too much (just get some tension on the valve) to open the valve up and allow oil through again. Try it with the filter off and a container to catch the oil so you can see how much to open the valve...