  1. O

    heatslave lockout

    thanks fella's, I'll give everything you said a try.STIX.
  2. O

    heatslave lockout

    The capacitor i have changed was the motor capacitor as it was below its rated value .However this has not cured the lockout's. I have also tried changing the transformer and solenoid but these did not work either so changed them back.Motor bearings are fine and the control box was changed by...
  3. O

    heatslave lockout

    in need of help with this one please. Worcester heatslave on a sealed system.It's had a number of issues recently including loss of pressure and intermittent lockouts.Fitted new PV,PRV,AAV and a capacitor.Pressure loss has greatly reduced but still goes down gradually,have checked all rad valves...
  4. O

    Myson Velaire Vitesse : Boiler firing problems

    How are you checking the capacitor value oilman ? Do you mean the uf value or something else, and what instrument are you using ?
  5. O

    Myson Velaire Vitesse : Boiler firing problems

    Don't dismantle the pump. It won't go back together properly.You can check if the pump coupling is ok . When did you last get a full service on the boiler by an experienced oil technician ? He/she will have the specialised equipment and knowledge to set the burner up and to identify problem...
  6. O

    Humming rad

    thanks trooper.
  7. O

    Humming rad

    Hi there, a rad on an open vented circuit has started to make a quite loud humming noise when the boiler( worcester heatslave) is powering the c/h. The system works ok with rads getting plenty hot and no air in them.Is it likely to be sludge, faulty rad valves (no trv's) , or something else you...
  8. O

    Bypass valve

    Well if you look on WB's web site the instructions show a bypass.
  9. O

    Bypass valve

    Is that no bypass on any new worcester ?
  10. O

    Bypass valve

    What if someone closes the rad valve manually ? Isn't it safer to fit a bypass regardless ?
  11. O

    Worcester heatslave 15/19 oil fired 'high pressure'

    Make sure the new vessel is OK. Could be a problem with the heat exchanger passing mains water through to the heating water.
  12. O

    Trianco oil, life expectancy ?

    You are right it is steel jacket. It was in need of a clean internally and the crud was somewhat sticky instead of the usual dry dusty dirt. However it was not terribly dirty. I wouldn't say it was undersized.Why go for non condensing ? Can't these only be fitted under certain conditions ?
  13. O

    Trianco oil, life expectancy ?

    Hi again ,hope you can help on this one. Trianco eurostar oil fired 10 years old. There is an inch of water in the base. I'm not sure how long this takes to accumulate but does not run over so presume the heat from the boiler causes it to evaporate at least as fast as it appears. Can't see...
  14. O

    Freeze or drain ?

    Hi guys, what ia the best method for replacing a complete 3 port valve (honeywell) ? Should i drain down the system, use arctic spray freezer kit, or some other method like bunging the tank ? As always your help is much needed and appreciated, Stix.
  15. O

    OVERFLOW driving us insane!!!

    And make sure that the sections of the new valve are screwed tightly together before fitting in the tank.
  16. O

    Combi boiler advice

    Maybe i am speaking out of turn but if the tank is leaking and the boiler although old is OK, why not just replace the tank ? You can still replace the boiler when it finally bites the dust , but without the need for a combi.
  17. O

    system capacity in litres ?

    I can find out the number of rads tomorrow but for tonight i would guess about 7. The MI says additional vessels may be fitted. I will check the vessel for blockages, thanks.
  18. O

    system capacity in litres ?

    Suppose i should elaborate. I have been called to a firebird combi 90 a couple of times recently because of leaks at various joints in the boiler.The vessel seems fine but the boiler is up to 2.5 bar when hot. According to the manual this is acceptable but seems high to me and i was wondering if...
  19. O

    system capacity in litres ?

    There is no substitute for experienced guesswork. I am still working on that one.Cheers.
  20. O

    system capacity in litres ?

    Hi folks, just reading a manual about combi's and pressure vessels and wondered how you calculate the total water content of a system so that the correct vessel can be fitted . All help as usual much appreciated ? STIX.