Search results

  1. N

    Smart thermostat help

    I am currently away from home so unable to check my system fully. But I do not think there is a thermostat on my hot water cylinder its self. The house used to have a coal fire with back boiler. The pipework from the back boiler has a thermostat just before it T's into the oil boiler feed and...
  2. N

    Smart thermostat help

    I am looking to get a smart thermostat system fitted either hive or nest. I would like to make sure I purchase the right thing. I currently have an oil boiler controlled by a 7 day digital programmer. I have 2 water tanks and a hot water cylinder in my loft. I can heat my hot water on its own...
  3. N

    Worcester Heatslave 12/14 going into lockout

    That’s my burner back up and running. Turns out it was the control box. I got a new upgraded control box off the shelf from plumb centre. (Danfoss 057H8102) Cheers for all the help lads.
  4. N

    Worcester Heatslave 12/14 going into lockout

    I’ve ordered up photocell and control box due to arrive today. Service engineer coming to fit and test so hopefully I’ll have heat tonight.
  5. N

    Worcester Heatslave 12/14 going into lockout

    So adjusted the pressure up from 80 to 100 psi. Still no better. Boiler fires up then cuts out after 4-5 seconds. All roads seem to point to the photocell or control box. We tried a test tonight. Took the photocell out and shone a light at it and fired up the boiler. It did exactly the same...
  6. N

    Worcester Heatslave 12/14 going into lockout

    Yes have done all the tests. Checked for spark prior to fitting blast tube and after. Solenoid checked all ok. It certainly sounds like it’s firing up. If I remove the burner as soon as it’s locked out the blast tube is damp with fuel and slightly warm. Just checked resistance on photocell...
  7. N

    Worcester Heatslave 12/14 going into lockout

    Have you found the problem with this. I am having exactly the same issue with my boiler which is also a danesmoor 12/14. Firstly my boiler stopped working. After much searching I found the supply line from pump to nozzle was chocked. I also noticed a cracked electrode so I’ve fitted new...
  8. N

    Vokera linea 28 fault

    Anyone able to give me some pointers? Gonna try checking the Venturi today see how that is.
  9. N

    Vokera linea 28 fault

    I am having a lot of problems with my vokera linea 28. The trouble I'm having is that I keep getting an error code 01 coming up. The code comes on when the central heating is being used. Once I turn the switch to off/reset then back on it fires back up again no problem. But this morning when I...
Back