    Noisy Boiler

    There are not many noises made from this boiler, but if it sounds like a aeroplane taking off now and again , you may find the heat exchanger clogged with debris, I would either put in a sludge remover and leave for a while and or clean the system.
  2. S

    Powermax 155x overheating

    ideas are if it has external plate heat exchanger that this could be blocked or change limit stat, ie out of caliberation , hope this helps.
  3. S

    baxi133he

    Didnt know how much it was , but i do know loading the premium up the following year is probably not on the cards, end of the day they are just all about having business year after year and although you have had a bad experiance that you may have another baxi in the future, keep you on board so...
  4. S

    baxi133he

    They will cover you straight away even if the boilers faulty,, no probs, number is or one of the numbers is 0800 032 7232, you will have to check the price etc but it does come down year after year, Then no matter how many parts and time your covered all the time.
  5. S

    baxi133he

    First thing i would do would be to gas analyse the boiler, look what its running at, this would tell you mixtures, ratio etc. Depending on what the result was make an informed decision what to do next. Been to some where the gas valve was a mile out and running incorrect and possibly dangerous...
  6. S

    baxi133he

    oh yes, tell the RGI to repressure the expansion vessel as well.
  7. S

    baxi133he

    If its sparking outside the combustion box, and shorting onto casing then its got to be poor insulation round the lead or loose connector .
  8. S

    baxi 105e

    Good one this ,,,, Try a new board if its never had one , 105e usually bullet proof on all other components, changed the board on a lot of these and cured all different faults,, other than that take out some insurance with baxi cos could get expensive , hope that helps.
  9. S

    potterton performa 28

    plate heat exchanger blocked,, clean or replace , better to replace,, if the problem is only happening on hot water , hope that helps
  10. S

    PCb faults

    :D That write up made me spill me tea, it was so funny !
  11. S

    Sludged up boiler heat ex qustion .....

    Thing is Harry, To be good at fault finding takes time, late days, headaches, going down the wrong path, and experiance, nobody is going to tell you any sort of shortcut or you would be as good as them without earning the hassle :wink:
  12. S

    baxi bahama 100 problem

    A bit of a nasty one this, I would change both flow switches first , see how that goes, then change plate heat ex, ,, hope that helps
  13. S

    Baxi 105e Water under Furnace

    Dont forget you may need new seals to pump manifold and new 3/4 washer to primary left hand side diverter, How many times rojaca half the bloody water section has to be changed cos you disturbed something,, not a bad job like you said matey if you have the room to work round the boiler, shawd :lol:
  14. S

    Baxi Bahama 100 - 3 way divertor valve cartridge

    I LOVE BAHAMA , :roll: THEYRE GREAT,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
  15. S

    noisey bedroom

    Can anybody help,, Had new bedroom fitted above garage , Thing is although i have a n amount of insulation below floor into garage, i can do with more soundproofing , can hear everything outside when i am in bed. its a nightmare, what options have i got and could i get builder back to sound...
  16. S

    No CH, No HW, Pump is always on

    sounds that micro switch is sticking, swap both 2 port valves , i am no sparky but have had this problem on a few occasions , changed the valves and it cured the problem, worked for me.
  17. S

    What a day! Combi 'fixed'!

    I would like to give that lady at no 21 a flying f***k :wink:
  18. S

    Bathroom radiator keeps on needing to be bled

    A bit of air collecting in a rad , not the end of the world ,,, Most people have to bleed a rad at sometime, dont worry be happy
  19. S

    Baxi 105e domestic hot water problem

    can only be a couple of things , board, plate heat ex or temp sensor hw, well 3 things,