  1. G

    Albion unvented cylider

    Fitted an Albion unvented cylinder (much against my own wishes) and having trouble with the dual stat Its wired in correctly i believe according to the sparky but it doesnt seem to be picking up the temperature change, the cylinder just keeps getting hotter and hotter All zone valves etc...
  2. G

    Noisy Boiler

    Whining noise is normally bearings so a fair assumption would be the fan or pump but if the manufacturers came out and said it was neither surely they should find out what it actually was because if never fitted one new that sounds like that I have had gas valves make a squealing noise before...
  3. G

    Fitting a Heated Towel Rail prior to tiling

    I like to chase the wall out so there are 2 tails sticking out (chrome looks nice) that will go straight into angled rad valves fitted to the bottom of the rail That way you see little pipe work and alls well hidden
  4. G

    Removing air from combi Ch system

    Heat exchanger might have a bleed or an auto air vent on the boiler which should normally be closed after commissioning may need to be opened for a while
  5. G

    Heating oil tank

    Hello fellow Powys resident, any more troubles let me know and could give you a free visit
  6. G

    Removing old sealant compounds

    It was a series of connected parts, the sealant was on a part I didn't want to remove. However I am a tight a**e :D actually meant the brush!!!! seems you are indeed :lol:
  7. G

    motorised valves

    Sure its not just the synchron?? Not found too many Honeywell actuator heads go completely to be honest
  8. G

    Removing old sealant compounds

    Buy a new one tight arse theyre only a pound or so!!! haha Seriously i use a stanley to get the tape off and wire brush the sealant off if needed
  9. G

    Oil Combi making grinding noise

    Grinding very different to kettling Kettling will be coming from the main heat exchanger which could be air especially after youve drained and filled back up again Is the grinding noise coming from the oil burner and not the water pump? Oil pumps are very noisy when they go
  10. G

    high pressure in circuit

    Try draining some from with a hose on the radiator circuit, shouldnt need much to drop pressure but make sure the filling loop is 100% off and youll need to bleed rads after
  11. G

    boiler problem

    Possibly the plate heat exchanger then (small silver rectangular unit) No filter as such to block it will be the fins inside so probably be a replacement and add a limescale reducer on the incoming mains supply
  12. G

    boiler problem

    Heat exchanger could be blocked, how hard is the water in your area, get much scale??
  13. G

    Running pipes in Floor - Joints?

    Id normally run 22 to the manifold and 15 to the rads, some use 10 but in plastic (YUK) the bore is tiny. Depends largely on system layout etc, but unless its huge you should be ok
  14. G

    sizing of unvented cylinder?

    Agre with Mr Agile, 170 - 210 if it was my house
  15. G

    Advice needed on New, reputable boilers and Gas safe

    All installers are different, in my part of the world its worcester bosch as nobody else can get engineers out as quickly and im an AI for them Only other boiler i fit is vaillant really, depends on your budget
  16. G

    Running pipes in Floor - Joints?

    If theres not too many i tend tun run them all back to one place in plastic (yuk) as theyre reasonably well suited to that and have all the connections on a manifold
  17. G

    FITTING NEW RADIATOR 10MM CENTRAL HEATING SYSTEM

    i was asking because i wasnt sure from the question if she meant she was connecting to an existing 10 or 8 supply, was it not ok to ask?
  18. G

    I want to ban ball type pump valves

    Theyll be leaking by now!!!!!!!!
  19. G

    FITTING NEW RADIATOR 10MM CENTRAL HEATING SYSTEM

    So you planning to run 2 radiators off this (possibly) 8mm supply installed around 1983?